Skip to main content
Siemens 3VA4195-4ED14-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4195-4ED14-0AA0 SENTRON MCCB, 1-Pole, 15 A, 65 kA

MPN3VA4195-4ED14-0AA0
Active

Siemens SENTRON 3VA4195-4ED14-0AA0, 1-pole molded-case circuit breaker, system protection, TM210 release, 15 A rated, 65 kA at 120 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA4195-4ED14-0AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
Product versionSystem protection
3VA4195-4ED14-0AA0 — Ratings
ParameterValue
Number of poles1
Current at 40 °C15 A
Current at 45 °C15 A
Current at 50 °C14 A
Current at 55 °C14 A
Current at 60 °C14 A
Current at 65 °C13 A
Current at 70 °C13 A
Switching capacity classS
Power loss, max.3.3 W
3VA4195-4ED14-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA4195-4ED14-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Main circuit connector arrangementLoad side: Circular conductor terminal
Protection class (IP), frontIP40
3VA4195-4ED14-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4195-4ED14-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4195-4ED14-0AA0 — Mechanical
ParameterValue
Height129.4 mm
Width25.4 mm
Depth75.1 mm
Height (in)5.1 in
Width (in)1 in
Depth (in)3 in

Product details

The Siemens 3VA4195-4ED14-0AA0 is a 1-pole SENTRON molded-case circuit breaker rated 15 A continuous at 40 °C, with a TM210 thermal-magnetic release providing LI protection (long-time and instantaneous). Interrupting capacity hits 65 kA at 120 VAC, 25 kA at 277 VAC, and 14 kA at 347 VAC — enough headroom for most commercial and light industrial service-entrance or distribution panels where high fault current is a given. The 25.4 mm width (1 inch) per pole means this breaker fits standard Siemens panelboard and loadcenter mounting slots without adapters.

Thermal derating and release settings

Rated current holds at 15 A through 45 °C ambient, then steps down to 14 A from 50 °C to 60 °C, and 13 A at 65 °C to 70 °C. The TM210 release has an adjustable long-time pickup (lg) set at 15 A and a fixed instantaneous trip (li) at 300 A. Maximum power loss is 3.3 W, which keeps heat rise manageable in a densely populated panel.

Dimensions are 75.1 mm deep, 25.4 mm wide, 129.4 mm tall (3 x 1 x 5.1 inches).