Skip to main content
Siemens 3VA4195-5ED24-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4195-5ED24-0AA0 SENTRON 2-Pole MCCB, 15 A, 85 kA

MPN3VA4195-5ED24-0AA0
Active

Siemens SENTRON 3VA4195-5ED24-0AA0, 2-pole molded-case circuit breaker, 15 A rated current at 40 °C, 85 kA interrupting capacity at 240 V AC, TM210 thermal-magnetic release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA4195-5ED24-0AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
3VA4195-5ED24-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Current at 40 °C15 A
Current at 45 °C15 A
Current at 50 °C14 A
Current at 55 °C14 A
Current at 60 °C14 A
Current at 65 °C13 A
Current at 70 °C13 A
Switching capacity classM
Breaking capacity at 240 V85 kA
Power loss, max.6.5 W
3VA4195-5ED24-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA4195-5ED24-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Protection class (IP), frontIP40
3VA4195-5ED24-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4195-5ED24-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4195-5ED24-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height129.4 mm
Width50.8 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)2 in
Depth (in)2.96 in

Product details

System protection MCCB with 85 kA interrupting capacity

At 480 V AC the interrupting rating drops to 35 kA, and at 600 Y/347 V it holds at 18 kA. These are the numbers your arc-flash study needs; the breaker's SCCR governs whether it coordinates with upstream gear or forces a redesign.

Rated continuous current is 15 A at 40 °C ambient. It holds that same 15 A at 45 °C, then steps down to 14 A at 50 °C through 60 °C, and finally 13 A at 65 °C and 70 °C. If your panel runs hot — near a drive stack or in a poorly ventilated enclosure — this derating curve is what determines whether the breaker nuisance-trips on a warm afternoon.

Dimensions are 50.8 mm wide, 129.4 mm tall, and 75.1 mm deep. Front face carries IP40 protection — suitable for general indoor panel use where tools or fingers won't contact live parts. No trip indicator on the front; you'll read the handle position to confirm tripped state.

Frequently asked questions

Will 3VA4195-5ED24-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0?

Both are 2-pole SENTRON 3VA MCCBs with the same pole spacing, so the 3VA4195-5ED24-0AA0 will physically fit the same panelboard mounting. However, the 3VA4195 is a system-protection design with a fixed TM210 release, while the 3VA1110 series typically uses a different trip curve — verify the coordination study before substituting.

MPN