Skip to main content
Siemens 3VA4195-6ED24-3AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4195-6ED24-3AA0 Circuit Breaker, 65 kA @ 480 V, 1

MPN3VA4195-6ED24-3AA0
Active

Siemens 3VA4 UL Frame 125, 2-pole circuit breaker, 65 kA @ 480 V, TM210 thermal-magnetic trip, In=15 A fixed, Ii=20 x In.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA4195-6ED24-3AA0 — Specifications
ParameterValue
Group codeP360
Product group5385
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : EAR99
Compliance with the substance restrictions according to RoHS directiveSince: 13-05-19

Product details

The Siemens 3VA4195-6ED24-3AA0 is a 2-pole circuit breaker from the 3VA4 UL Frame 125 series, rated for line protection with a TM210 thermal-magnetic trip unit.

The TM210 trip is set with a fixed overload Ir of 15 A (equal to In) and a short-circuit pickup Ii of 20 × In (300 A magnetic). That means no field-adjustable dials for overload — the 15 A is locked in, which simplifies BOM consistency but means you verify the load current matches before panel build. The 2-pole construction fits standard DIN-rail or panel-mount footings in the 3VA4 family; the 65 kA SCCR at 480 V is the same across all H-class breakers in this frame.

RoHS compliance dated from 13-05-19; Export controls are AL: N / ECCN: EAR99 — no special license required for standard industrial shipments.

Frequently asked questions

What is the interrupting rating of 3VA4195-6ED24-3AA0?

It is rated 65 kA at 480 V, which is the H (high) breaking capacity class for the 3VA4 UL Frame 125. That covers most industrial service-entrance and feeder applications where fault currents exceed 25 kA.

What compliance documentation does this breaker carry?

RoHS compliant since 13-05-19. REACH Article 33 declares lead (CAS 7439-92-1) above 0.1% w/w. Export classification is AL: N / ECCN: EAR99.

Where can I buy 3VA4195-6ED24-3AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here.

MPN
3VA4195-6ED24-3AA0