Siemens 3VA9144-0JK11 — Circuit Breaker Accessories

Siemens 3VA9144-0JK11 SENTRON Accessory, Circular Conductor

MPN3VA9144-0JK11
Active

Siemens SENTRON 3VA9144-0JK11, circular conductor terminal accessory, wire connector TC1.3 14 AWG…1/0 Cu with control wire voltage tap-off, 0.7 in strip length, UL/CSA 14-1/0 CU9, IEC 1.5-50 mm² CU NNL.

Independent distributor — new & surplus sourcingAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA9144-0JK11 — Identification
ParameterValue
Product designationaccessories
3VA9144-0JK11 — Other specifications
ParameterValue
Product versioncircular conductor terminal
Wire stripping length0.7 in
UL-marking (of terminals)14-1/0 CU9 TC1.3 CMC UR CSA
IEC-marking (of terminals)1.5-50 mm² CU NNL
For copper cable (Solid, maximum)10 AWG
For copper cable (Solid, minimum)14 AWG
For copper cable (Stranded, maximum)1/0 AWG
For copper cable (Stranded, minimum)14 AWG
For copper cable (Finely stranded, maximum)1/0 AWG
For copper cable (Finely stranded, minimum)14 AWG

Product details

The Siemens 3VA9144-0JK11 is a SENTRON circular conductor terminal accessory — a wire connector TC1.3 rated for 14 AWG through 1/0 AWG copper, with an integrated control wire voltage tap-off. It ships as a 4-unit pack and is designed for the 3VA6 150/250 frame breakers. Strip length is 0.7 in (about 18 mm). The terminal carries UL/CSA marking 14-1/0 CU9 TC1.3 CMC UR CSA and IEC marking 1.5-50 mm² CU NNL, so it's accepted in both North American and European panel builds.

Lifecycle status is current/active per Siemens — this is not a phase-out or NRND line item. It's a standard accessory for the SENTRON 3VA molded-case breaker family, so it moves as a BOM-consistent spare rather than a specialty oddment. For a panel builder or MRO planner, this means the 3VA9144-0JK11 is a straight replacement for any 3VA6 150/250 installation that needs the circular terminal with tap-off. No last-time-buy clock ticking.

Wire range and fit

Solid copper: 14 AWG min, 10 AWG max. Stranded and finely stranded: 14 AWG min, 1/0 AWG max. That covers most panel power and control wiring from a #14 control circuit up to a 1/0 feeder tap. The control wire voltage tap-off is the feature that saves a separate splice block — one less connection point in the panel, one less thing to torque-check during commissioning.