Skip to main content
Siemens 3VA9153-0JA11 — Circuit Breaker Accessories

Siemens 3VA9153-0JA11 SENTRON Box Terminal, TS1.1, 3 Units

MPN3VA9153-0JA11
Active

Siemens SENTRON 3VA9153-0JA11, box terminal TS1.1, 3 units, 1.5…70 mm², accessories for 3VA1 100/160.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA9153-0JA11 — Identification
ParameterValue
Product designationaccessories
AccessoriesBox terminal
3VA9153-0JA11 — Other specifications
ParameterValue
Solid14 - 10 AWG: 45 lb-in
Stranded14 - 6 AWG: 45 lb-in 4 AWG - 3/0: 70 lb-in
Finely stranded14 - 6 AWG: 45 lb-in 4 AWG - 3/0: 70 lb-in
Stripped length0.5 in
Design of the productbox terminal 3 units
Designation (Of the terminal)TS1.1
For copper cable (Solid, maximum)10 AWG
For copper cable (Solid, minimum)14 AWG
For copper cable (Stranded, maximum)3/0 AWG
For copper cable (Stranded, minimum)14 AWG
For copper cable (Finely stranded, maximum)3/0 AWG
For copper cable (Finely stranded, minimum)14 AWG
Type of electrical connection (With control wire tap)No

Product details

Terminal specs and torque values

The Siemens SENTRON 3VA9153-0JA11 is a box terminal designated TS1.1, supplied as a set of three units. It is an accessory intended for 3VA1 100/160 molded-case circuit breakers, covering conductor cross-sections from 1.5 mm² up to 70 mm². Maximum conductor count per terminal is 3 conductors of 6x 13 mm x 0.5 mm; minimum is 1 conductor of 9 x 9 mm x 0.8 mm. There is no control-wire tap on this terminal.

This box terminal mounts directly onto the line and load lugs of a 3VA1 100/160 breaker. The TS1.1 design accepts the full stranded range up to 3/0 AWG, so it handles feeder conductors typical for 100 A and 160 A frames without needing a separate reducer.

Frequently asked questions

What is the torque spec for solid copper on 3VA9153-0JA11?

For solid copper conductors from 14 AWG to 10 AWG, the terminal torque is 45 lb-in. Stranded and finely stranded conductors from 14 AWG up to 3/0 AWG also take 45 lb-in; from 4 AWG to 3/0 the torque is 70 lb-in.

What is the maximum conductor size for 3VA9153-0JA11?

The maximum conductor size is 3/0 AWG for stranded and finely stranded copper. The terminal accepts up to 3 conductors of 6x 13 mm x 0.5 mm maximum, or 1 conductor of 9 x 9 mm x 0.8 mm minimum.

Where can I buy 3VA9153-0JA11 and how is it quoted?

The 3VA9153-0JA11 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
3VA9153-0JA11