Skip to main content
Siemens 3VA9224-0RL30

Siemens 3VA9224-0RL30 SENTRON RCD820, 250 A, 4-Pole

MPN 3VA9224-0RL30
Active

Siemens SENTRON RCD820 advanced residual current device, type A, load-side mounted, 4-pole, In=250 A, adjustable residual current 0.03–30 A, adjustable non-tripping time 0–10000 ms, accessory for 3VA2 molded case circuit breakers.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3VA9224-0RL30 specifications
ParameterValue
Poles4
Mountingscrew fixing
Depth86 mm
Width139.6 mm
Height115 mm

Product details

The Siemens 3VA9224-0RL30 is an RCD820 advanced residual current device from the SENTRON family, designed as a load-side mounted accessory for 3VA2 molded case circuit breakers. It's a 4-pole, type A RCD rated at 250 A operational current at AC, covering the full range from 100 to 690 V supply voltage. This is the module that bolts onto the line side of a 3VA2 breaker to add ground-fault protection without replacing the entire breaker — a clean retrofit for an existing panel.

The adjustable residual current response spans from 0.03 A up to 30 A — ten selectable thresholds (0.03, 0.05, 0.1, 0.3, 0.5, 1, 3, 5, 10, 30 A). That range covers everything from sensitive personnel protection at 30 mA through to equipment protection at 30 A for large feeder circuits. The non-tripping time is equally flexible: adjustable from 0 ms up to 10,000 ms in eleven steps (0, 0.06, 0.15, 0.3, 0.5, 1.0, 2.0, 3.0, 5.0, 10.0 s). This lets you delay tripping through inrush or transient leakage that would nuisance-trip a fixed RCD, while still clearing a sustained fault. The pre-alarm indication triggers at 30% and 60% of the set residual current — a heads-up before the trip threshold is reached, useful for predictive maintenance on a motor feeder or conveyor line. Type A design means it detects both sinusoidal AC residual currents and pulsating DC residual currents — the kind generated by single-phase rectifiers, VFD front ends, and switching power supplies common in modern control panels. That makes it a better fit for mixed-load panels than a basic AC-type RCD. The module supports remote-controlled tripping and communication with residual current equipment, so it can be integrated into a building management or SCADA system for remote indication and trip control. It also offers a selectable RCD or monitoring mode — you can use it purely as a monitor without tripping the breaker, which is handy for commissioning or tracking intermittent ground faults.

Mounts via screw fixing directly onto the load side of a 3VA2 molded case circuit breaker — no DIN rail required, no extra wiring between breaker and RCD. The infeed can come from the top or bottom, giving flexibility in tight enclosures. Main circuit connection is by busbar connection, keeping the assembly compact.

MPN
3VA9224-0RL30