Skip to main content
Siemens 3VA9244-0JA12 — Circuit Breaker Accessories

Siemens 3VA9244-0JA12 SENTRON Box Terminal, TS1.4, 4 AWG–350

MPN3VA9244-0JA12
Active

Siemens SENTRON box terminal TS1.4, 4 units, 4 AWG–350 kcmil stranded, for 3VA6 150/250 molded-case circuit breakers.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3VA9244-0JA12 — Identification
ParameterValue
Product designationaccessories
AccessoriesBox terminal

Other specifications

3VA9244-0JA12 — Other specifications
ParameterValue
Stranded4 - 1 AWG: 70 lb-in 1/0 - 350 kcmil: 140 lb-in
Finely stranded4 - 1 AWG: 70 lb-in 1/0 - 350 kcmil: 140 lb-in
Stripped length0.8 in
Design of the productbox terminal 4 units
Designation (Of the terminal)TS1.4
For copper cable (Stranded, maximum)350 kcmil
For copper cable (Stranded, minimum)4 AWG
For copper cable (Finely stranded, maximum)350 kcmil
For copper cable (Finely stranded, minimum)4 AWG
Type of electrical connection (With control wire tap)No

Product details

The Siemens 3VA9244-0JA12 is a SENTRON box terminal (designation TS1.4) sold as a set of four units. It is the line-side or load-side lug kit for 3VA6 150/250 A frame molded-case circuit breakers — the accessory that transitions from the breaker's bus bars to the field cable. This terminal does not include a control wire tap — it is a straight power connection, no auxiliary tap-off.

What the torque and wire range mean on the panel floor

The TS1.4 terminal is designed for the 3VA6 breaker's footprint. It mounts directly to the breaker's line/load studs — no adapter plate needed. Four units per set cover the three phases plus neutral on a 3-pole + N breaker.

Frequently asked questions

Where can I buy 3VA9244-0JA12 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at that time.

Will 3VA9244-0JA12 drop into a panel that was specified around 5SL4363-7 without rewiring?

No — 5SL4363-7 is a SENTRON miniature circuit breaker (3-pole, 400 VAC, C-curve), not a terminal accessory. The 3VA9244-0JA12 is a box terminal for the 3VA6 molded-case breaker family; it cannot be substituted for an MCB or vice versa.

What is the stranded wire range and torque for 3VA9244-0JA12?

Stranded copper: 4 AWG to 350 kcmil. Torque: 70 lb-in for 4–1 AWG, 140 lb-in for 1/0–350 kcmil. Strip length: 0.8 in.

MPN
3VA9244-0JA12