Skip to main content
Siemens 3VA9467-0HA20

Siemens 3VA9467-0HA20 SENTRON Motor Operator, 110-230V AC

MPN 3VA9467-0HA20
Active

Siemens SENTRON 3VA9467-0HA20, motorized operating mechanism (MO) accessory, 110-230 V AC / 110-250 V DC control supply, 250 VA, for 3VA1 and 3VA2 400/630 A frame breakers.

$293.37 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3VA9467-0HA20 specifications
ParameterValue
Depth149 mm
Width138 mm
Height92 mm

Product details

The Siemens 3VA9467-0HA20 is a motorized operating mechanism (MO) from the SENTRON accessory line, designed to remotely open and close 3VA1 and 3VA2 molded-case circuit breakers in the 400 A and 630 A frame sizes. It accepts a dual-rated control supply of 110–230 V AC (at 60 Hz) or 110–250 V DC, drawing 250 VA apparent power during operation. Make time is 1.7 s typical, break time 1.3 s typical — fast enough for emergency switching but not for arc-flash mitigation duty (that requires a dedicated shunt trip or undervoltage release). This is a panel-mount accessory that bolts onto the breaker front; the 149 mm depth, 138 mm width, and 92 mm height mean it adds roughly the footprint of a second breaker to the enclosure depth. Plan the gland plate and wireway accordingly — the control wiring enters at the mechanism, not the breaker terminals.

Control supply and environmental limits

The control supply voltage range is wide — 110 V minimum to 230 V maximum at AC 60 Hz, and 110 V minimum to 250 V maximum at DC — so it works across standard North American and European control voltages without a separate transformer tap. The operating temperature span of -40 °C to 80 °C covers most indoor and outdoor enclosures; the -40 °C floor matters for cold-climate installations where a standard mechanism might stiffen or fail to engage. Stripped length for the control wires is 7 mm — a common dimension for spring-cage or screw terminals on the mechanism block. The 250 VA apparent power draw is the peak during the make/break stroke; steady-state holding current is lower, but the control transformer must be sized for the inrush.

MPN
3VA9467-0HA20