Siemens 3VA9673-0JC24 — Circuit Breaker Accessories

Siemens 3VA9673-0JC24 SENTRON TA4.1 Voltage Tap, 2x400-750 k

MPN3VA9673-0JC24
Active

Siemens SENTRON TA4.1 circular conductor terminal voltage tap, 2 cables, external, 3 units, for copper/aluminum 400-750 kcmil, with control wire tap-off.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3VA9673-0JC24 — Identification
ParameterValue
Product designationaccessories
AccessoriesWire connector

Other specifications

3VA9673-0JC24 — Other specifications
ParameterValue
Stranded240 300 mm2: 42.4 Nm
Stripped length1.1 in
Design of the productcircular conductor terminal voltage tap, 2 cables, external, 3 units
Designation (Of the terminal)TA4.1
For copper cable (Stranded, maximum)750 kcmil
For copper cable (Stranded, minimum)400 kcmil
For aluminum cable (Stranded, maximum)750 kcmil
For aluminum cable (Stranded, minimum)400 kcmil
For copper cable (Finely stranded, maximum)750 kcmil
For copper cable (Finely stranded, minimum)400 kcmil
Type of electrical connection (With control wire tap)Yes

Product details

The Siemens SENTRON 3VA9673-0JC24 is a TA4.1 circular conductor voltage tap — a terminal accessory that lets you tap voltage off the main bus without breaking the cable run. It handles two cables per unit, copper or aluminum, stranded or finely stranded, from 400 kcmil up to 750 kcmil. Each set ships three units, enough to cover a three-phase panel. The built-in control wire tap (voltage tap-off) means you can pull a smaller-gauge sense or control wire directly from the main conductor — no separate fuse block or splice required. That saves a DIN rail position and a wiring step in the panel.

Torque and strip length — what they mean on the bench

For stranded cable in the 240–300 mm² range (roughly 500–600 kcmil), the terminal torque spec is 42.4 Nm. That's a firm pull on a long-handled torque wrench — not a screwdriver job. The stripped length is 1.1 in (about 28 mm), which tells your wireman how much insulation to remove for full contact in the compression saddle.

Frequently asked questions

What cable sizes does the TA4.1 voltage tap accept?

It accepts copper or aluminum cable, stranded or finely stranded, from 400 kcmil minimum to 750 kcmil maximum per conductor.

How do I get current pricing and availability for 3VA9673-0JC24?

Availability and current pricing are confirmed at quote time against an RFQ through independent distribution — send your quantity and target delivery window for a firm quote.

Does 3VA9673-0JC24 work with 5SL4363-7 breakers?

No — this voltage tap is designed for the SENTRON 3VA55/3VA65/3VA66 molded-case breaker frames, not for the 5SL series miniature breakers. The mounting interface and bus-bar pitch are different.