Skip to main content
Siemens 3VA9673-0JC44 — Circuit Breaker Accessories

Siemens 3VA9673-0JC44 SENTRON Wire Connector, 4/0-600 kcmil,

MPN3VA9673-0JC44
Active

Siemens SENTRON TA4.4 wire connector, 4 cables, external, 3 units, 4/0-600 kcmil Cu/Al, 42.4 Nm, with control-wire voltage tap-off.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3VA9673-0JC44 — Identification
ParameterValue
Product designationaccessories
AccessoriesWire connector

Other specifications

3VA9673-0JC44 — Other specifications
ParameterValue
Stranded120 300 mm2: 42.4 Nm
Finely stranded120 185 mm2: 42.4 Nm
Product versioncircular conductor terminal voltage tap, 4 cables, external, 3 units
Stripped length0.9 / 1.75 in
Designation (Of the terminal)TA4.4
For copper cable (Stranded, maximum)600 kcmil
For copper cable (Stranded, minimum)4/0 AWG
For aluminum cable (Stranded, maximum)600 kcmil
For aluminum cable (Stranded, minimum)4/0 AWG
For copper cable (Finely stranded, maximum)600 kcmil
For copper cable (Finely stranded, minimum)4/0 AWG
Type of electrical connection (With control wire tap)Yes

Product details

The Siemens SENTRON 3VA9673-0JC44 is a TA4.4 circular-conductor terminal with an integrated control-wire voltage tap-off, sold as a 3-unit pack for external mounting. Each terminal accepts four cables in the 4/0 AWG to 600 kcmil range for both copper and aluminum stranded conductors, with a termination torque of 42.4 Nm for 120–300 mm² stranded and 120–185 mm² finely stranded copper. The voltage tap-off lets you pick up control power directly at the breaker line terminals — no separate tap block needed, which saves a DIN-rail position and one wiring step during panel build.

Wire range and termination

Strip length is 0.9 / 1.75 in depending on conductor type. The 42.4 Nm torque spec applies across the full stranded and finely stranded copper range; aluminum conductors in the same 4/0–600 kcmil range terminate at the same torque, so no re-torque step is needed when switching material on the same breaker.

Frequently asked questions

What wire sizes and torque does 3VA9673-0JC44 accept?

It accepts 4/0 AWG to 600 kcmil copper or aluminum stranded conductors, with a termination torque of 42.4 Nm for the 120–300 mm² stranded and 120–185 mm² finely stranded ranges.

What does the control-wire voltage tap-off on 3VA9673-0JC44 do?

It lets you pick up control power directly at the breaker line terminals through the terminal body, eliminating a separate tap block and saving one DIN-rail position.

MPN