Skip to main content
Siemens 3VA9978-0BD12 — Circuit Breaker Accessories

Siemens 3VA9978-0BD12 SENTRON Auxiliary Release, 24V DC

MPN3VA9978-0BD12
Active

Siemens SENTRON 3VA9978-0BD12 universal auxiliary release, 24V DC, for 3VA4/5/6 molded-case circuit breakers, 3 slots, 28.8 mm depth, 25.7 mm width, 65.1 mm height.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

3VA9978-0BD12 — Identification
ParameterValue
Product designationAccessories
AccessoriesAuxiliary release

Mechanical

3VA9978-0BD12 — Mechanical
ParameterValue
Width25.7 mm
Height65.1 mm
Depth28.8 mm

Other specifications

3VA9978-0BD12 — Other specifications
ParameterValue
Number of slots3
Stripped length10 mm
Degree of pollution3
Overvoltage categoryIII
Stripped length [In]0.4 in
Design of the productauxiliary release
Surge voltage resistance4 kV
Consumed active power (at DC, maximum)20 W
Type of electrical connection (For auxiliary circuit)AWG18 / 750 mm

Product details

The Siemens 3VA9978-0BD12 is a SENTRON universal auxiliary release designed for the 3VA4, 3VA5, and 3VA6 series of molded-case circuit breakers. It operates on a 24V DC control supply, drawing up to 20 W at maximum DC load. This is the part that trips the breaker remotely — think emergency-stop circuits, undervoltage protection schemes, or PLC-driven shunt-trip commands from a safety relay. Physically, it occupies three slots in the breaker's accessory bay, with a footprint of 25.7 mm wide by 65.1 mm tall by 28.8 mm deep. The auxiliary circuit connection accepts AWG18 wire with a 10 mm (0.4 in) strip length — standard for panel wiring.

The surge voltage resistance of 4 kV and the overvoltage category III rating align with IEC 60947-2 requirements for breaker accessories in industrial installations. If your panel is specified around 3VA4/5/6 breakers, this release drops in without modification — no adapter plate, no wiring harness change.

A 24 VDC supply feeding this release needs to deliver at least 0.83 A continuously to hold the coil energized; inrush at pickup will be higher. Factor that into your DC load budget — especially if the same supply also feeds PLC outputs or safety relays. Overvoltage category III confirms it's suitable for fixed-installation distribution panels, not just downstream equipment. Together, these two ratings tell the panel builder this release is built for the same environment as the breaker it mounts in.

Frequently asked questions

Where can I buy 3VA9978-0BD12?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the depth of 3VA9978-0BD12?

The listed depth is 28.8 mm. Combined with a width of 25.7 mm and height of 65.1 mm, it occupies three accessory slots in a 3VA4/5/6 breaker.

Will 3VA9978-0BD12 fit a panel built around 5SY4140-7?

No — 5SY4140-7 is a miniature circuit breaker (MCB), not a 3VA series molded-case breaker. The 3VA9978-0BD12 is an auxiliary release designed specifically for 3VA4/5/6 breakers; it does not mount in an MCB's accessory bay.

MPN
3VA9978-0BD12