Skip to main content
Siemens 3VM1050-2ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1050-2ED42-0AA0 SENTRON MCCB, 4P, 50A, 500A max

MPN3VM1050-2ED42-0AA0
Active

Siemens SENTRON 3VM1050-2ED42-0AA0, 4-pole molded case circuit breaker, 50 A rated at 40 °C, 500 A frame, TM210 thermal-magnetic release, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VM1050-2ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VM1050-2ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classC
Breaking capacity at 240 V53 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V14 kA
Breaking capacity at 500 V8 kA
Power loss, max.15 W
3VM1050-2ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VM1050-2ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1050-2ED42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1050-2ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1050-2ED42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.12 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

The TM210 thermal-magnetic release handles overloads thermally and short circuits magnetically — no electronic trip unit, no communication function, no voltage or undervoltage release on this variant.

Rated 50 A straight across from 40 °C to 50 °C, then it begins to taper: 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. The 15 W maximum power loss is modest for a 4-pole 50 A MCCB; ventilation in the enclosure is still advisable.

MPN
3VM1050-2ED42-0AA0