Skip to main content
Siemens 3VM1120-3EE42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1120-3EE42-0AA0 Circuit Breaker, 25kA @ 415V, 20A

MPN3VM1120-3EE42-0AA0
Active

Siemens 3VM1 IEC frame 160 circuit breaker, breaking capacity class N, Icu=25kA @ 415V, 4-pole, line protection TM220, ATFM, In=20A, overload protection Ir=14A...20A, short-circuit protection Ii=16 x In, N conductor unprotected, nut keeper kit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VM1120-3EE42-0AA0 — Specifications
ParameterValue
Group codeP360
Product group5377
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
SeriesOrdering Data Overview
Export control regulationsAL : N / ECCN : N
Compliance with the substance restrictions according to RoHS directiveSince: 01-06-12

Product details

Circuit breaker 3VM1120-3EE42-0AA0 — 25 kA @ 415 V, 4-pole, TM220

The Siemens 3VM1120-3EE42-0AA0 is a 4-pole IEC frame 160 circuit breaker from the 3VM1 series, rated for line protection with a thermal-magnetic TM220 trip unit. Its 25 kA breaking capacity at 415 V (class N) means it can safely interrupt fault currents up to that level without upstream cascading — a key coordination point for panel builders sizing the main breaker. Overload protection is adjustable from 14 A to 20 A (Ir), and short-circuit protection is fixed at 16 x In (320 A). The N conductor is unprotected, so this breaker is intended for 3-phase + N systems where the neutral is not switched or protected — typical in European-style distribution panels. The nut keeper kit is included, simplifying DIN-rail or panel-mount installation in enclosures where captive hardware saves assembly time.

Lifecycle and compliance

RoHS compliant since 01-06-12. REACH Article 33 disclosure: lead (CAS-No. 7439-92-1) above 0.1% w/w in the current candidate list. No export restrictions (AL: N / ECCN: N).

Frequently asked questions

What is the breaking capacity of 3VM1120-3EE42-0AA0?

Icu = 25 kA at 415 V (breaking capacity class N).

What is the overload protection range for this breaker?

Overload protection Ir is adjustable from 14 A to 20 A; short-circuit protection Ii is fixed at 16 x In (320 A).

What compliance documentation does this breaker have?

RoHS compliant since 01-06-12. REACH Article 33: lead (CAS-No. 7439-92-1) above 0.1% w/w. No export restrictions (AL: N / ECCN: N).

Where can I buy 3VM1120-3EE42-0AA0?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current pricing and lead time.

MPN
3VM1120-3EE42-0AA0