Skip to main content
Siemens 3VM1125-5EE32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1125-5EE32-0AA0 SENTRON MCCB, 25 A, 3-Pole, 187 k

MPN3VM1125-5EE32-0AA0
Active

Siemens SENTRON 3VM1125-5EE32-0AA0, molded case circuit breaker, line protection, 3-pole, 25 A, TM220 thermal-magnetic trip, 187 kA at 240 V AC, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VM1125-5EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VM1125-5EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C24 A
Current at 60 °C24 A
Current at 65 °C23 A
Current at 70 °C23 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V17 kA
Power loss, max.9 W

Protection & Trip Unit

3VM1125-5EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout

Construction & Connection

3VM1125-5EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40

Accessories & Functions

3VM1125-5EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0

Environmental

3VM1125-5EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VM1125-5EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Siemens 3VM1125-5EE32-0AA0 — SENTRON MCCB, 25 A, 187 kA SCCR

The Siemens 3VM1125-5EE32-0AA0 is a SENTRON molded case circuit breaker (MCCB) for line protection, carrying a 25 A continuous rating at 40 °C and a TM220 thermal-magnetic trip unit. It's a 3-pole frame with a 187 kA interrupting capacity at 240 V AC, stepping down to 121 kA at 415 V and 76 kA at 440 V — numbers that tell you this breaker is built for high-fault utility or transformer-fed panels where the available short-circuit current is significant. Rated operational voltage is 690 V AC, with a DC rating of 500 V. Insulation voltage is 800 V, so the internal clearances are sized for 600 V class gear. Front protection is IP40 — fine for a dry indoor panel, but not for washdown zones.

Current derating and thermal limits

The 25 A rating holds flat from 40 °C through 50 °C. At 55 °C it derates to 24 A, and at 70 °C it's 23 A. That's a shallow slope — the breaker doesn't shed much capacity until you're well above typical panel ambient. Maximum power loss is 9 W, which is modest for a 3-pole 25 A frame. Operating temperature range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The storage limits govern handling and warehousing, not running conditions.

Physical fit and panel integration

The 3VM1125-5EE32-0AA0 measures 130 mm high, 76.2 mm wide, and 70 mm deep. That's a standard 3-pole MCCB footprint for a 25 A frame — it'll drop into most panel layouts without re-drilling the backplate. No undervoltage release, no voltage trigger, no communication module, no ground-fault monitoring on this variant; it's a straight thermal-magnetic line-protection breaker. No trip indicator on the front, so you'll need to read the handle position or wire an auxiliary contact separately if remote status is required.

Frequently asked questions

What are the key interrupting ratings for 3VM1125-5EE32-0AA0?

At 240 V AC the SCCR is 187 kA; at 415 V it's 121 kA; at 440 V it's 76 kA; at 500 V it drops to 17 kA. These are the maximum fault currents the breaker can safely interrupt at each voltage level.

What is the closest functional alternative to 3VM1125-5EE32-0AA0?

The 3VA1020-2ED32-0DD0 is a functional peer in the same SENTRON family — same 25 A, 3-pole, thermal-magnetic platform. The 3VM series is the economy line; the 3VA series adds modular accessories and higher SCCR options. Panel cutouts are similar, but verify the depth before swapping — the 3VA frame is slightly deeper.

Where can I buy 3VM1125-5EE32-0AA0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
3VM1125-5EE32-0AA0