Siemens 3VM1132-3ED16-0AA2 SENTRON MCCB, 1-pole, 32 A, 53 kA

MPN3VM1132-3ED16-0AA2

Siemens SENTRON 3VM1132-3ED16-0AA2, molded case circuit breaker, 1-pole, 32 A, TM210 thermal-magnetic release, 53 kA at 240 V AC, 8 kA at 415 V AC, IP40 front, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1132-3ED16-0AA2 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1132-3ED16-0AA2 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V53 kA
Breaking capacity at 415 V8 kA
Power loss, max.4 W
3VM1132-3ED16-0AA2 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1132-3ED16-0AA2 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1132-3ED16-0AA2 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1132-3ED16-0AA2 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1132-3ED16-0AA2 — Mechanical
ParameterValue
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

SENTRON 3VM1132-3ED16-0AA2 — 1-pole MCCB, 32 A, TM210 release

Breaking capacity hits 53 kA at 240 V AC and 8 kA at 415 V AC — the 240 V figure covers most North American panelboard fault levels; the 415 V figure suits European 400 V distribution where the available fault current is lower. The 125 V DC rating (max Ue) extends its use to DC control circuits. Thermal derating is minimal: holds 32 A from 40 °C through 50 °C, drops only 1 A at 55 °C and 60 °C, and sits at 30 A at 70 °C. That means the breaker can be packed into a warm enclosure without oversizing the frame. Dimensions are 70 mm deep, 25.4 mm wide (1 inch), 130 mm tall — the 1-inch width matches standard panelboard pole spacing, so it slots into existing 1-pole positions without extra bus work.

Integration notes

The 1-pole form factor and 25.4 mm width let it drop into standard DIN-rail or panel-mount MCCB slots. No undervoltage release, no motor drive, no communication module — it is a straight thermal-magnetic breaker for basic branch-circuit protection.

Frequently asked questions

What is the breaking capacity of 3VM1132-3ED16-0AA2 at 240 V and 415 V?

53 kA at 240 V AC and 8 kA at 415 V AC.

Where can I buy 3VM1132-3ED16-0AA2 and how is it quoted for volume?

The part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VM1132-3ED16-0AA2