Skip to main content
Siemens 3VM1132-3ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1132-3ED12-0AA0 SENTRON 1P MCCB, 32 A, 53 kA at 2

MPN3VM1132-3ED12-0AA0
Active

Siemens SENTRON 3VM1132-3ED12-0AA0, 1-pole molded case circuit breaker, 32 A rated current, TM210 thermal-magnetic release, LI protection, 53 kA at 240 VAC, 7.5 kA at 415 VAC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1132-3ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1132-3ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classN
Breaking capacity at 240 V53 kA
Breaking capacity at 415 V7.5 kA
Power loss, max.3.5 W
3VM1132-3ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1132-3ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1132-3ED12-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1132-3ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1132-3ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.12 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.1 in
Width (in)1 in
Depth (in)2.8 in

Product details

1-pole MCCB, 32 A, TM210 — line protection for panel feeders

The Siemens SENTRON 3VM1132-3ED12-0AA0 is a 1-pole molded case circuit breaker rated 32 A continuous at 40 °C, with a thermal-magnetic TM210 release configured for LI (long-time and instantaneous) protection. The interrupting capacity is 53 kA at 240 VAC and 7.5 kA at 415 VAC, which gives headroom for high-fault installations where the available fault current is substantial at the lower voltage. The fixed instantaneous trip is set at 320 A (10× In), so it clears hard faults fast without nuisance tripping on moderate inrush. This breaker occupies a single 25.4 mm (1 in) module width on the DIN rail, with a depth of 70 mm and height of 130 mm.

That flat profile simplifies panel design: you don't need to oversize for a warm cabinet unless ambient exceeds 50 °C.

DC capability and voltage limits

The maximum rated operational voltage for DC applications is 125 V. The insulation voltage (Ui) is rated 500 V. For DC switching capacity values, Siemens directs users to the 3VA Molded Case Circuit Breaker Manual. The breaker does not include a neutral conductor upgrade option, ground-fault monitoring, or communication function.

Frequently asked questions

Where can I buy 3VM1132-3ED12-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is the interrupting capacity of this MCCB?

The interrupting capacity is 53 kA at 240 VAC and 7.5 kA at 415 VAC.

What is the width of 3VM1132-3ED12-0AA0?

The width is 25.4 mm (1 inch), occupying a single module on the DIN rail.

What type of overcurrent release does this breaker use?

It uses a TM210 thermal-magnetic release configured for LI protection (long-time and instantaneous). The instantaneous trip is fixed at 320 A.

MPN
3VM1132-3ED12-0AA0