Siemens 3VM1150-4EE36-0AA2 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VM1150-4EE36-0AA2 MCCB, 50 A, 121 kA at 240 V

MPN3VM1150-4EE36-0AA2

SENTRON 3VM1150-4EE36-0AA2, IEC molded case circuit breaker, 3-pole, 50 A rated continuous current, TM220 thermal-magnetic release, 121 kA breaking capacity at 240 V AC, 76 kA at 415 V AC, IP40 front protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1150-4EE36-0AA2 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1150-4EE36-0AA2 — Ratings
ParameterValue
Number of poles3
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V53 kA
Breaking capacity at 500 V11.9 kA
Power loss, max.14.6 W
3VM1150-4EE36-0AA2 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
3VM1150-4EE36-0AA2 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1150-4EE36-0AA2 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1150-4EE36-0AA2 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Product details

The SENTRON 3VM1150-4EE36-0AA2 is a 3-pole IEC molded case circuit breaker on a 160 A frame, fitted with a TM220 thermal-magnetic overcurrent release and rated for 50 A continuous current at 40 °C. The LI protective function (long-time and instantaneous) covers cable and busbar protection in line distribution panels.

Breaking capacity steps down with voltage: 121 kA at 240 V, 76 kA at 415 V, 53 kA at 440 V, and 11.9 kA at 500 V. For a site electrical engineer working on selectivity, the S-class switching capacity (36 kA Icu at 415 V per the description) gives headroom for downstream coordination with smaller MCCBs or MCBs. The 50 A continuous rating holds flat through 50 °C, then derates to 49 A at 55 °C and 45 A at 70 °C — useful when the breaker sits in a warm enclosure near other heat sources.

Mounting and connection details

Front-connected box terminals accept the main circuit wiring. The IP40 front protection suits enclosed panel mounting — not washdown, but fine for dry indoor switchgear. The 160 A frame size gives physical room for larger cable lugs. No auxiliary contacts are fitted as standard (0 CO contacts), and no motor drive or neutral conductor upgrade is offered on this variant.

Frequently asked questions

What is the breaking capacity of 3VM1150-4EE36-0AA2 at 240 V and 415 V?

At 240 V AC the interrupting rating is 121 kA; at 415 V AC it is 76 kA. The breaker also carries 53 kA at 440 V and 11.9 kA at 500 V.

Where can I buy 3VM1150-4EE36-0AA2 and how is it quoted?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

MPN
3VM1150-4EE36-0AA2