The SENTRON 3VM1196-4EE46-0AA2 is a 4-pole molded case circuit breaker (MCCB) rated for 16 A continuous current across ambient temperatures from 40 °C to 55 °C, derating to 15 A at 60 °C through 70 °C. Its interrupting capacity hits 121 kA at 240 V AC, 76 kA at 415 V, 53 kA at 440 V, and 11.9 kA at 500 V — the S switching capacity class means it handles high fault currents typical of industrial distribution panels and motor control centers. The TM220 thermal-magnetic release provides LI protection (long-time and instantaneous), so it covers both overload and short-circuit faults without needing an external relay. Box terminals on the front simplify busbar or cable connections in a standard panel layout.

SENTRON 3VM1196-4EE46-0AA2 MCCB, 16 A, 121 kA at 240 V
SENTRON 3VM1196-4EE46-0AA2, Molded case circuit breaker, 4-pole, 16 A rated continuous current at 40 °C, TM220 overcurrent release, LI protective function, S switching capacity class, 121 kA at 240 V AC, box terminal front connection.
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Product version | Line protection |
| Parameter | Value |
|---|---|
| Number of poles | 4 |
| Current at 40 °C | 16 A |
| Current at 45 °C | 16 A |
| Current at 50 °C | 16 A |
| Current at 55 °C | 16 A |
| Current at 60 °C | 15 A |
| Current at 65 °C | 15 A |
| Current at 70 °C | 15 A |
| Switching capacity class | S |
| Breaking capacity at 240 V | 121 kA |
| Breaking capacity at 415 V | 76 kA |
| Breaking capacity at 440 V | 53 kA |
| Breaking capacity at 500 V | 11.9 kA |
| Power loss, max. | 10.6 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | TM220 |
| Parameter | Value |
|---|---|
| Main circuit connection type | box terminal |
| Main circuit connector arrangement | Front connection |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Communication function | No |
| Measurement function | No |
| Motor drive option | No |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
Product details
Frequently asked questions
What is the interrupting capacity of 3VM1196-4EE46-0AA2 at 240 V?
It is rated 121 kA at 240 V AC, with 76 kA at 415 V, 53 kA at 440 V, and 11.9 kA at 500 V — the S switching capacity class covers high-fault industrial mains.
Where can I buy 3VM1196-4EE46-0AA2?
This MCCB is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time.
What compliance documentation is available for this MCCB?
The evidence does not list specific compliance certificates (UL, IEC, RoHS, REACH) for this order code. Request documentation at quote time if your project requires it.