Skip to main content
Siemens 3VM1196-4EE46-0AA2 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VM1196-4EE46-0AA2 MCCB, 16 A, 121 kA at 240 V

MPN3VM1196-4EE46-0AA2

SENTRON 3VM1196-4EE46-0AA2, Molded case circuit breaker, 4-pole, 16 A rated continuous current at 40 °C, TM220 overcurrent release, LI protective function, S switching capacity class, 121 kA at 240 V AC, box terminal front connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VM1196-4EE46-0AA2 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1196-4EE46-0AA2 — Ratings
ParameterValue
Number of poles4
Current at 40 °C16 A
Current at 45 °C16 A
Current at 50 °C16 A
Current at 55 °C16 A
Current at 60 °C15 A
Current at 65 °C15 A
Current at 70 °C15 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V53 kA
Breaking capacity at 500 V11.9 kA
Power loss, max.10.6 W
3VM1196-4EE46-0AA2 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
3VM1196-4EE46-0AA2 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1196-4EE46-0AA2 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1196-4EE46-0AA2 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Product details

The SENTRON 3VM1196-4EE46-0AA2 is a 4-pole molded case circuit breaker (MCCB) rated for 16 A continuous current across ambient temperatures from 40 °C to 55 °C, derating to 15 A at 60 °C through 70 °C. Its interrupting capacity hits 121 kA at 240 V AC, 76 kA at 415 V, 53 kA at 440 V, and 11.9 kA at 500 V — the S switching capacity class means it handles high fault currents typical of industrial distribution panels and motor control centers. The TM220 thermal-magnetic release provides LI protection (long-time and instantaneous), so it covers both overload and short-circuit faults without needing an external relay. Box terminals on the front simplify busbar or cable connections in a standard panel layout.

Frequently asked questions

What is the interrupting capacity of 3VM1196-4EE46-0AA2 at 240 V?

It is rated 121 kA at 240 V AC, with 76 kA at 415 V, 53 kA at 440 V, and 11.9 kA at 500 V — the S switching capacity class covers high-fault industrial mains.

Where can I buy 3VM1196-4EE46-0AA2?

This MCCB is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — stock and lead time are confirmed at quote time.

What compliance documentation is available for this MCCB?

The evidence does not list specific compliance certificates (UL, IEC, RoHS, REACH) for this order code. Request documentation at quote time if your project requires it.

MPN
3VM1196-4EE46-0AA2