Skip to main content
Siemens 3VM1220-5GD42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1220-5GD42-0AA0 SENTRON MCCB, 200 A, 4-Pole, 187

MPN3VM1220-5GD42-0AA0
Active

Siemens SENTRON 3VM1220-5GD42-0AA0, Molded case circuit breaker, 4-pole, 200 A, TM210 release, 187 kA at 240 V, 121 kA at 415 V, 76 kA at 440 V, 30 kA at 500 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1220-5GD42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1220-5GD42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V30 kA
Power loss, max.42 W
3VM1220-5GD42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1220-5GD42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1220-5GD42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1220-5GD42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1220-5GD42-0AA0 — Mechanical
ParameterValue
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.2 in
Width (in)5.5 in
Depth (in)2.8 in

Product details

This breaker punches hard on interrupting capacity: 187 kA at 240 V, 121 kA at 415 V, 76 kA at 440 V, and 30 kA at 500 V. Those are the maximum fault currents it can safely clear at each voltage level. For a 480 V panel with a 65 kA available fault current, the 76 kA at 440 V rating gives you comfortable headroom — no need to cascade upstream. The 30 kA at 500 V covers the high-end industrial bus. The 690 V insulation voltage (Ui) means the internal creepage and clearance are built for 600 V class systems.

The 3VM1220-5GD42-0AA0 measures 70 mm deep, 140 mm wide, and 158 mm tall. Front protection is IP40, so it's sealed against tools and fingers but not washdown. No motor drive option, no communication module; it's a straightforward thermal-magnetic breaker for hardwired distribution.

MPN
3VM1220-5GD42-0AA0