Skip to main content
Siemens 3VM1220-3ED42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1220-3ED42-0AA0 SENTRON MCCB, 200 A, 4-Pole, 76 k

MPN3VM1220-3ED42-0AA0

Siemens SENTRON 3VM1220-3ED42-0AA0, 4-pole molded case circuit breaker, 200 A rated continuous current, TM210 thermal-magnetic release, breaking capacities 76 kA at 240 V AC, 53 kA at 415 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1220-3ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1220-3ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classN
Breaking capacity at 240 V76 kA
Breaking capacity at 415 V53 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V11.9 kA
Power loss, max.42 W
3VM1220-3ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VM1220-3ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1220-3ED42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1220-3ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1220-3ED42-0AA0 — Mechanical
ParameterValue
Height158 mm
Width140 mm
Depth70 mm
Height (in)6.2 in
Width (in)5.5 in
Depth (in)2.8 in

Product details

The Siemens 3VM1220-3ED42-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for 200 A continuous current across a 40 °C to 50 °C ambient band — no derating needed until you cross 55 °C, where it steps down to 194 A, then 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. Four poles, line protection version, no ground-fault monitoring or N-conductor protection built in.

This MCCB interrupts 76 kA at 240 V AC, 53 kA at 415 V AC, 32 kA at 440 V AC, and 11.9 kA at 500 V AC. The 415 V figure is the one most panel builders will anchor to for European 400 V three-phase distribution; the 240 V rating covers North American 240/120 V split-phase or 240 V delta feeds. Maximum rated operational voltage for DC applications is 500 V.

Panel footprint and integration

Maximum power loss is 42 W, so factor that into thermal calculations for sealed cabinets.

Frequently asked questions

Where can I buy 3VM1220-3ED42-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at the time of quote.

What is the breaking capacity of 3VM1220-3ED42-0AA0 at 415 V?

53 kA at 415 V AC. It also interrupts 76 kA at 240 V, 32 kA at 440 V, and 11.9 kA at 500 V.

Does 3VM1220-3ED42-0AA0 include ground fault monitoring?

No, this is a line protection version without ground fault monitoring and without N-conductor protection.

MPN
3VM1220-3ED42-0AA0