Skip to main content
Siemens 4EM5008-0BK00 — Line/Load Reactors

Siemens 4EM5008-0BK00 SIDAC Smoothing Choke, 110A DC, 800V

MPN4EM5008-0BK00

Siemens SIDAC, smoothing choke, 4EM5008-0BK00, 1-phase, 110A DC, 800V, 60 µH, IP00, free cable ends.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EM5008-0BK00 — Inductance & Impedance
ParameterValue
Rated inductance0.00006H
Energy content0.363W
4EM5008-0BK00 — Identification
ParameterValue
Product designationGlaettungsdrossel
4EM5008-0BK00 — Electrical
ParameterValue
Rated operating voltage800V
Number of phases1
Voltage typeDC
Rated operating frequency2 500Hz
4EM5008-0BK00 — Losses & Thermal
ParameterValue
Power loss, coil (W)1W
Power loss, iron core (W)1W
Rated ambient temperature40°C
4EM5008-0BK00 — Approvals
ParameterValue
Thermal class (IEC 60085)F
4EM5008-0BK00 — Mechanical
ParameterValue
Main-circuit connection typefree cable endings
IP protection ratingIP00
Parallel windings selectableNo
Height0.087m
Width0.097m
Depth0.131m

Product details

Smoothing choke for DC-link filtering

The Siemens SIDAC 4EM5008-0BK00 is a 1-phase smoothing choke rated for 110 A DC maximum, 99 A nominal, with an 800 V insulation voltage and 60 µH inductance. It is designed for DC-link ripple filtering in drives and power supplies, built to EN 61558-2-20. The 2500 Hz operating frequency suits it for high-frequency switching converter outputs where reducing current ripple protects downstream capacitors and extends semiconductor life.

The 110 A maximum DC current and 800 V rated voltage define the continuous load envelope — this choke will saturate above that current, so it must be sized to the drive's peak DC bus current, not the motor nameplate. The 60 µH inductance at 2500 Hz gives a specific impedance; verify it matches your converter's switching frequency and ripple current target. Thermal class F (155 °C) insulation per IEC 60085 means it can run hot in a closed panel, but the 1 W copper loss plus 1 W iron loss (2 W total) is modest — no forced cooling needed in most cabinets.

IP00 open-frame construction

IP00 means no enclosure — the choke is a bare wound component with free cable ends for termination. The free cable ends (0.2–2.5 mm² typical) let you wire directly to the DC bus terminals; no lug or connector is supplied. Dimensions are 97 mm wide × 87 mm high × 131 mm deep — fits a standard 100 mm DIN rail footprint but requires clearance around the magnetic field.

Frequently asked questions

What is the 4EM5008-0BK00 used for?

It is a DC-link smoothing choke that filters ripple current from a single-phase rectifier or DC supply, reducing harmonic stress on capacitors and improving power quality in drives and power converters.

MPN
4EM5008-0BK00