Siemens 4EM5011-0AK00 — Line/Load Reactors

4EM5011-0AK00 Siemens CPU, PROFINET IRT, MRP, PID control

MPN4EM5011-0AK00

Siemens CPU 4EM5011-0AK00, PROFINET IRT with MRP redundancy manager, integrated PID controllers for temperature and valves, 32 kB input/output process image, 35 x 147 x 129 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EM5011-0AK00 — Mechanical
ParameterValue
Height147 mm
Width35 mm
Depth129 mm

Product details

PROFINET IRT and MRP redundancy

The Siemens 4EM5011-0AK00 CPU supports PROFINET IRT for deterministic, isochronous real-time communication — critical for motion control and high-speed I/O synchronization. It also functions as an MRP redundancy manager and/or MRP client, with a maximum ring size of 50 devices. MRPD is available when IRT is active, enabling media redundancy for isochronous data. This makes the CPU suitable for ring-topology networks where a single cable break must not drop the line.

Integrated PID control for temperature and valves

Two PID controller variants are built in: PID-Temp with integrated optimization for temperature loops, and for valve actuators. Each controller supports up to 40 probes. This eliminates the need for a separate loop controller on applications like oven zones, autoclaves, or HVAC valve banks — the CPU handles the closed-loop logic directly.

Process image and programming languages

The process image allocates 32 kbyte for inputs and 32 kbyte for outputs — all inputs and outputs are mapped into the image, so no manual remapping is needed for standard I/O. Programming options include LAD, FBD, STL, SCL, and GRAPH, covering ladder, function block, structured text, and sequential control. DCP (Discovery and Configuration Protocol) is supported for network setup.

Communication interfaces and protocols

The CPU communicates via PROFINET at 100 Mbps. MODBUS TCP, TCP/IP, UDP, HTTP, HTTPS, SNMP, and LLDP are all supported. DHCP is not enabled — addressing is fixed or configured via DCP. A maximum of 6 communication modules (PROFINET + PROFIBUS) can be inserted in total. I&M data (I&M0 to I&M3) is present for asset identification.

Environmental range and diagnostics

On-board diagnostics include an ERROR LED and a MAINT LED for quick fault indication. The hardware clock maintains timekeeping across power cycles. Dimensions are 35 mm wide, 147 mm high, 129 mm deep — fits standard 35 mm DIN-rail enclosures.

Frequently asked questions

What does DCP (Yes) mean on this CPU?

DCP (Discovery and Configuration Protocol) is supported, meaning the CPU can be identified and assigned an IP address via PROFINET without a separate DHCP server. This is standard for Siemens PROFINET devices and simplifies initial network commissioning.

What does FBD (Yes) mean on this CPU?

FBD (Function Block Diagram) is a supported programming language. It allows graphical wiring of logic blocks, useful for signal conditioning and closed-loop control sequences. The CPU also supports LAD, STL, SCL, and GRAPH.

MPN
4EM5011-0AK00