Skip to main content
Siemens 4EM5200-1CB00 — Line/Load Reactors

Siemens 4EM5200-1CB00 Commutating Choke, 1-Phase, 400 V, 36

MPN4EM5200-1CB00

Siemens 4EM5200-1CB00 commutating choke for converters, 1-phase, 400 V AC, 36 A rated, 40 A max, 0.0012 H, IP00, screw terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EM5200-1CB00 — Inductance & Impedance
ParameterValue
Rated inductance0.0012H
Relative inductive voltage drop4%
4EM5200-1CB00 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EM5200-1CB00 — Electrical
ParameterValue
Rated operating voltage400V
Number of phases1
Rated current (DC)49A
Voltage typeAC
Rated operating frequency50Hz
4EM5200-1CB00 — Losses & Thermal
ParameterValue
Power loss, coil (W)19.8W
Power loss, iron core (W)33.7W
Rated ambient temperature40°C
4EM5200-1CB00 — Approvals
ParameterValue
Thermal class (IEC 60085)B
4EM5200-1CB00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00
Height0.131m
Width0.121m
Depth0.128m

Product details

The Siemens 4EM5200-1CB00 is a 1-phase commutating choke (also called a line reactor or commutation reactor) designed for converter applications. The inductance is 0.0012 H (1.2 mH), and the relative inductive voltage drop at rated conditions is 4%.

The 36 A rated current (40 A maximum) sets the continuous load capacity for motor-drive or converter line-side filtering. The 4% impedance is typical for a line reactor that limits harmonic distortion and reduces peak currents on the converter input — a standard value for most variable-frequency drives in industrial panels. The 0.0012 H inductance, combined with the 400 V / 50 Hz rating, means this choke is sized for a single-phase converter branch drawing up to 36 A.

This choke mounts in a converter or drive panel, typically on the input side of a variable-frequency drive or DC drive to smooth current ripple and limit inrush. The screw-type terminals (main circuit connection) accept standard power wiring. Dimensions: 0.128 m deep, 0.121 m wide, 0.131 m high — fits a standard cabinet footprint. The thermal class B (IEC 60085) insulation system allows a 40 °C ambient with a 19.8 W coil loss and 33.7 W iron-core loss; derate if ambient exceeds 40 °C.

Frequently asked questions

What are the key electrical ratings of 4EM5200-1CB00?

Rated current 36 A, maximum 40 A, operating voltage 400 V AC at 50 Hz, inductance 0.0012 H, relative inductive drop 4%.

MPN
4EM5200-1CB00