Siemens 4EP3200-0AK00 — Line/Load Reactors

Siemens 4EP3200-0AK00 Mains Choke for VFD, 3A, 9.8 mH, 400/4

MPN4EP3200-0AK00

Siemens 4EP3200-0AK00 mains choke (Netzdrossel f. FU), 3-phase AC, rated 3A, 9.8 mH, 400/460 V, IP00, screw/tab terminals, Class B insulation, 45°C ambient.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EP3200-0AK00 — Inductance & Impedance
ParameterValue
Rated inductance0.0098H
Relative inductive voltage drop4%
4EP3200-0AK00 — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EP3200-0AK00 — Electrical
ParameterValue
Rated operating voltage400, 460V
Number of phases3
Voltage typeAC
Rated operating frequency50 ... 60Hz
4EP3200-0AK00 — Losses & Thermal
ParameterValue
Rated ambient temperature45°C
4EP3200-0AK00 — Approvals
ParameterValue
Thermal class (IEC 60085)B
4EP3200-0AK00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals / tab terminals
IP protection ratingIP00
Height0.108m
Width0.088m
Depth0.057m
4EP3200-0AK00 — Other specifications
ParameterValue
Rated value3A

Product details

What this choke does in the panel

The Siemens 4EP3200-0AK00 is a 3-phase AC mains choke — a line reactor — sized for frequency converter (VFD) input. Rated for 3 A continuous at 400/460 V, 50-60 Hz, it sits between the supply and the drive to smooth line-side harmonics, limit inrush current, and protect the VFD rectifier from grid spikes. The 9.8 mH inductance gives a 4% voltage drop at rated current — a typical figure for a moderate impedance choke that doesn't starve the drive of voltage under load. At 0.057 m deep and 0.088 m wide, it's a compact block that wires up clean on a backplate or DIN-rail bracket. The IP00 open-frame construction means it's for enclosure mounting only — keep it away from washdown zones and conductive dust. Screw-type and tab terminals accept standard ring lugs or fork terminals; no special crimp tool needed.

Thermal and duty considerations

Rated for 45°C ambient with Class B insulation (130°C thermal class per IEC 60085). In a packed enclosure with other heat sources, derate if the internal air temperature exceeds 45°C. The 3 A rating is the continuous thermal current — not a short-time or overload figure. If the VFD draws intermittent peaks above 3 A, the choke will saturate and lose inductance, so size it for the drive's continuous input current, not the motor FLA.

Frequently asked questions

What is the 4EP3200-0AK00 used for?

It is a 3-phase AC mains choke (line reactor) for frequency converters. It sits on the input side of a VFD to reduce harmonic distortion, limit inrush current, and protect the drive rectifier from voltage transients.

Where can I buy the 4EP3200-0AK00?

Sourced to order against an RFQ through independent distribution channels. Submit a request for quote to confirm current availability and pricing.

What are the key electrical ratings of the 4EP3200-0AK00?

Rated 3 A continuous at 400/460 V AC, 3-phase, 50-60 Hz. Inductance is 9.8 mH with a 4% voltage drop at rated current. Ambient temperature rating is 45°C with Class B insulation.

What are the physical dimensions of the 4EP3200-0AK00?

Width 0.088 m, depth 0.057 m, height 0.108 m. Open-frame IP00 construction with screw-type and tab terminals.