Siemens 4EP3600-8DS00 — Line/Load Reactors

Siemens 4EP3600-8DS00 Commutating Choke, 16.2A, 400V, 3-Phas

MPN4EP3600-8DS00

Siemens 4EP3600-8DS00 commutating choke for converter, 3-phase, 400V AC, 16.2A rated, 18A max, 1.6mH, IP00, screw terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

4EP3600-8DS00 specifications
ParameterValue
Type of voltageAC
Type of electrical connection for main current circuitscrew-type terminals
Operating voltage rated value400V
Relative inductive drop in voltage on the measurement level current, voltage and frequency4%
Power loss [W] of the coil39W
Power loss [W] of the iron core9.1W
Operating frequency rated value50Hz
Phase number3
Ambient temperature rated value40°C
Depth0.078m
Width0.148m
Height0.139m
Thermal class acc. to IEC 60085B
Rated value16.2A
At DC rated value22A
Protection class IPIP00
Inductivity rated value0.0016H

Product details

The Siemens 4EP3600-8DS00 is a three-phase commutating choke for converter front-end duty. It limits current rise rates and reduces harmonic distortion. Rated for 400 V AC at 50 Hz, it carries 16.2 A continuous with 18 A maximum.

The 16.2 A rated current (18 A maximum) at 400 V AC three-phase sets the continuous load this choke can handle without exceeding its thermal class B (130 °C) insulation system. The 39 W coil loss and 9.1 W iron core loss total about 48 W of heat that must be dissipated into the enclosure — IP00 means no enclosure of its own, so it relies on the panel's airflow. The DC rated value of 22 A indicates the choke can handle a higher DC-side current, which matters if the converter's DC-link current exceeds the AC line rating — for example, in a regenerative drive or one with a high crest factor.

The 4EP3600-8DS00 measures 0.148 m wide by 0.139 m tall by 0.078 m deep. The 3-phase design with a common core means all three lines share the same magnetic path; verify that the panel's phase-to-phase and phase-to-ground clearances meet the 400 V AC working voltage.

Frequently asked questions

What is 4EP3600-8DS00 used for?

It is a commutating choke (line reactor) for converter front-end duty. It limits current rise rates, reduces harmonic distortion, and protects DC-link capacitors from line notching and commutation spikes in three-phase AC drives and power converters.