Skip to main content
Siemens 4EP3601-8DS00 — Line/Load Reactors

Siemens 4EP3601-8DS00 Commutating Choke, 14.4A, 500V

MPN4EP3601-8DS00

Siemens 4EP3601-8DS00 commutating choke for converter, 3-phase, 500V AC, 14.4A rated current, 16A max, 1.8mH, IP00, screw-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EP3601-8DS00 — Inductance & Impedance
ParameterValue
Rated inductance0.0018H
Relative inductive voltage drop4%
4EP3601-8DS00 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EP3601-8DS00 — Electrical
ParameterValue
Rated operating voltage500V
Number of phases3
Rated current (DC)19.6A
Voltage typeAC
Rated operating frequency50Hz
Peak current20A
4EP3601-8DS00 — Losses & Thermal
ParameterValue
Power loss, coil (W)37W
Power loss, iron core (W)7.5W
Rated ambient temperature40°C
4EP3601-8DS00 — Approvals
ParameterValue
Thermal class (IEC 60085)B
4EP3601-8DS00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00
Height0.126m
Width0.148m
Depth0.078m

Product details

Commutating choke for converter duty

The Siemens 4EP3601-8DS00 is a three-phase commutating choke (also called a line reactor or converter reactor) designed to limit current rise and reduce harmonic distortion on the input of variable-frequency drives and other power converters. Rated for 500V AC at 50 Hz, it carries a continuous rated current of 14.4 A with a maximum of 16 A and a peak current capability of 20 A. The 1.8 mH inductance provides a relative inductive voltage drop of 4% at rated current, frequency, and voltage — a typical value for drive input reactors that keeps the voltage drop low enough to avoid starving the DC bus while still smoothing the line current. The choke is built for continuous industrial duty with a thermal class B winding (130 °C rise) at a 40 °C ambient.

IP00 — panel-mount only

Protection class IP00 means the choke has no enclosure — it is a bare component intended for mounting inside a control cabinet or power panel where the cabinet itself provides the environmental seal. The screw-type terminals accept stranded or solid copper conductors for the main circuit connection.

Frequently asked questions

What are the key electrical ratings for 4EP3601-8DS00?

Three-phase, 500V AC, 50 Hz. Continuous rated current is 14.4 A, maximum current is 16 A, peak current is 20 A. Inductance is 1.8 mH with a 4% relative inductive voltage drop at rated conditions. Power loss is 37 W in the coil plus 7.5 W in the iron core.

What compliance documentation does this brand provide for 4EP3601-8DS00?

The choke is UL and CSA recognized under EN 61558-2-20, the standard for separating transformers and reactors. Thermal class B per IEC 60085. The product designation and ratings confirm it meets the applicable industrial safety standards for converter input reactors.

Where can I buy 4EP3601-8DS00 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
4EP3601-8DS00