Siemens 4EP3605-0AS00 — Line/Load Reactors

Siemens 4EP3605-0AS00 Commutating Choke, 3-Phase 230V AC, 56

MPN4EP3605-0AS00

Siemens SENTRON series, commutating choke for converter, 3-phase, 230V AC, 56A maximum / 50A rated, 0.15 mH, IP00, screw-type terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP3605-0AS00 — Inductance & Impedance
ParameterValue
Rated inductance0.00015H
Relative inductive voltage drop2%

Identification

4EP3605-0AS00 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EP3605-0AS00 — Electrical
ParameterValue
Rated operating voltage230V
Number of phases3
Rated current (DC)68.6A
Voltage typeAC
Rated operating frequency50Hz

Losses & Thermal

4EP3605-0AS00 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C

Approvals

4EP3605-0AS00 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP3605-0AS00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00

Other specifications

4EP3605-0AS00 — Other specifications
ParameterValue
Rated value50A

Product details

What It Is and What It Does

The Siemens 4EP3605-0AS00 is a three-phase commutating choke (line reactor) designed for converter front-ends. It limits current rise during commutation, reducing harmonic distortion and protecting the DC link from switching transients. Rated for 50 A continuous with a 56 A maximum thermal current (Ithmax) at 50 Hz, 230 V AC three-phase. The 0.15 mH inductance (0.147 mH per the spec line) gives a 2 % relative inductive voltage drop — meaning it's sized for moderate impedance, not heavy filtering.

Key Ratings and What They Mean for Fit

The 56 A maximum (Ithmax) is the thermal limit under worst-case conditions — the choke can handle short-term overloads up to that level without exceeding Class B insulation temperature rise (ambient 40 °C). The 50 A rated current (I LN) is the continuous design point for normal operation. At DC, the rated value is 68.6 A — relevant if the choke is used on the DC side of a converter, though the primary application is AC line-side commutation. IP00 means no enclosure protection — the choke is an open-frame component intended for installation inside a panel or cabinet. Screw-type terminals accept standard lug or ring-terminal connections.

Where It Goes in the System

Mounts in the AC line between the supply and the converter input, typically in a control cabinet. The open-frame design (IP00) requires clean, dry, non-conductive surroundings — not for washdown or outdoor use without an enclosure. Rated ambient temperature is 40 °C with Class B insulation, so derating is needed if cabinet internal temperature exceeds that. The 50 Hz operating frequency is standard for mains applications.

Frequently asked questions

What is the maximum current rating of 4EP3605-0AS00?

The maximum thermal current (Ithmax) is 56 A at 50 Hz. The continuous rated current (I LN) is 50 A.

Will 4EP3605-0AS00 drop into a panel specified around 5SL3232-6MB?

No — the 5SL3232-6MB is a miniature circuit breaker (MCB), a completely different component class. The 4EP3605-0AS00 is a three-phase choke for converter input; it serves a different function and has a different footprint.