Skip to main content
Siemens 4EP3700-1BK00 — Line/Load Reactors

Siemens 4EP3700-1BK00 Mains Choke, 3-Phase 480V 17.3A

MPN4EP3700-1BK00

Siemens SENTRON 4EP3700-1BK00 mains choke (line reactor) for variable frequency drives, 3-phase, 480V AC, 17.3A maximum current, 1.7 mH, IP00, screw/tab terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP3700-1BK00 — Inductance & Impedance
ParameterValue
Rated inductance0.0017H
Relative inductive voltage drop4%

Identification

4EP3700-1BK00 — Identification
ParameterValue
Product designationNetzdrossel f. FU

Electrical

4EP3700-1BK00 — Electrical
ParameterValue
Rated operating voltage460, 480V
Number of phases3
Voltage typeAC
Rated operating frequency50 ... 60Hz

Losses & Thermal

4EP3700-1BK00 — Losses & Thermal
ParameterValue
Power loss, coil (W)46W
Power loss, iron core (W)10.5W
Rated ambient temperature45°C

Approvals

4EP3700-1BK00 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP3700-1BK00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals / tab terminals
IP protection ratingIP00
Height0.153m
Width0.178m
Depth0.105m

Product details

What it is and what it does

The Siemens 4EP3700-1BK00 is a three-phase mains choke (line reactor) designed for installation upstream of a variable frequency drive (VFD). Its job is to smooth the input current, reduce harmonic distortion, and limit inrush current spikes that would otherwise stress the drive's rectifier and DC bus capacitors. Rated for a continuous current of 15.6 A with a maximum of 17.3 A, the choke handles the full-load current of a typical 7.5 kW to 11 kW drive on a 480 V three-phase supply. The 1.7 mH inductance delivers a 4 % relative inductive voltage drop at rated conditions — a standard impedance value that balances harmonic mitigation against voltage drop across the choke. The 4 % voltage drop means that at full rated current, the drive sees about 461 V instead of 480 V at its input terminals. That is within the operating window of most industrial drives, but if your drive is already marginal on input voltage (e.g., a 460 V unit on a 480 V line), factor the 4 % drop into your voltage budget.

Key ratings and what they mean for fit

The choke is rated for an operating voltage of 460 V to 480 V AC at 50/60 Hz. That covers the common North American 480 V and international 460 V industrial three-phase supplies. Total power loss is 56.5 W — 46 W in the coil and 10.5 W in the iron core. That heat must be dissipated inside the enclosure. In a sealed IP54 cabinet, that 56.5 W adds to the thermal load; factor it into your ventilation or cooling calculation. Protection class IP00 means the choke has no enclosure — it is an open-frame component intended for mounting inside a panel that provides the environmental protection. The screw-type and tab terminals accept standard ring lugs or fork terminals for the main power connections.

Panel integration notes

The choke measures 0.178 m wide by 0.153 m tall by 0.105 m deep. It is a panel-mount component, not DIN-rail clip-on. Plan for screw-mounting on a backplate with clearance for the screw/tab terminals on top. Because it is IP00, the choke must be mounted inside an enclosure that provides at least finger-safe protection (IP2X or better). Keep at least 50 mm clearance around the choke for airflow to carry away the 56.5 W of heat.

Frequently asked questions

What compliance documentation does 4EP3700-1BK00 carry?

The choke is UL/CSA recognized under EN 61558-2-20, the standard for chokes and reactors. That covers the North American market. For EU compliance, the EN 61558-2-20 listing implies CE marking via the harmonized standard. RoHS and REACH documentation should be available from Siemens on request.

MPN
4EP3700-1BK00