Siemens 4EP3700-5US00 — Line/Load Reactors

Siemens 4EP3700-5US00 Mains Choke, 3-Phase 40A, 0.35mH

MPN4EP3700-5US00
Active

Siemens 4EP3700-5US00 mains choke for frequency converters, 3-phase AC, 40A max current, 0.35mH inductance, 2% voltage drop, IP00 open-frame, screw terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP3700-5US00 — Inductance & Impedance
ParameterValue
Rated inductance0.00035H
Relative inductive voltage drop2%

Identification

4EP3700-5US00 — Identification
ParameterValue
Product designationNetzdrossel f. FU

Electrical

4EP3700-5US00 — Electrical
ParameterValue
Rated operating voltage400, 480V
Rated current (AC)36A
Number of phases3
Current (AC), max.40A
Voltage typeAC
Rated operating frequency50 ... 60Hz

Losses & Thermal

4EP3700-5US00 — Losses & Thermal
ParameterValue
Power loss, coil (W)41.8W
Power loss, iron core (W)11.4W
Rated ambient temperature40°C

Approvals

4EP3700-5US00 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP3700-5US00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00
Height0.153m
Width0.178m
Depth0.105m

Product details

What It Is and Where It Goes

The Siemens 4EP3700-5US00 is a three-phase mains choke for the input side of variable-frequency drives. It carries 40 A maximum continuous current with 0.00035 H inductance and 2 % voltage drop at rated conditions. The IP00 open-frame construction requires enclosure mounting. Screw-type terminals handle power connections, and thermal class B insulation keeps the core and coil within safe limits at 40 °C ambient.

What the Ratings Mean for Your Panel

The 2 % voltage drop at rated current indicates the choke is sized for moderate harmonic mitigation without excessive voltage headroom loss. Power loss splits into 41.8 W in the coil and 11.4 W in the iron core. That heat must be evacuated from the enclosure. Dimensions are 0.178 m wide, 0.153 m high, and 0.105 m deep. The IP00 design requires clearance for airflow and creepage distances inside the cabinet.

Frequently asked questions

What compliance certifications does 4EP3700-5US00 carry?

The choke is designed to EN 61558-2-20 and carries UL/CSA recognition per the manufacturer's specification.

MPN
4EP3700-5US00