Siemens 4EP4001-3MS00 — Line/Load Reactors

Siemens SIDAC 4EP4001-3MS00 Filter Reactor, 19.7 A, 400 V

MPN4EP4001-3MS00

Siemens SIDAC series, filter reactor, 3-phase, 400 V AC, 50 Hz, 19.7 A rated current, 5.67 % relative throttling factor, IP00, screw/tab terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EP4001-3MS00 — Inductance & Impedance
ParameterValue
Rated inductance0.0025H
Relative throttling factor5.67%
Filter resonant frequency210Hz
Rated reactive power (filter bank)12 500var
4EP4001-3MS00 — Identification
ParameterValue
Product designationfilter reactor
4EP4001-3MS00 — Electrical
ParameterValue
Rated operating voltage400V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EP4001-3MS00 — Losses & Thermal
ParameterValue
Total power loss (W)89W
Rated ambient temperature40°C
4EP4001-3MS00 — Approvals
ParameterValue
Thermal class (IEC 60085)B
4EP4001-3MS00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals / tab terminals
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Product details

What this reactor does on the line

The Siemens SIDAC 4EP4001-3MS00 is a 3-phase filter reactor rated for 400 V AC at 50 Hz, with a rated current of 19.7 A and a maximum current of 21.9 A. Its 0.0025 H inductance and 5.67 % relative throttling factor are sized to attenuate harmonic currents and limit inrush on the line side of a variable-frequency drive or similar non-linear load. The reactor's resonant frequency is 210 Hz, and the filter bank's rated reactive power is 12 500 var. This places the trap below the 5th harmonic at 50 Hz fundamental.

The reactor measures 0.219 m wide, 0.179 m tall, and 0.143 m deep. IP00 protection means it is an open-frame component intended for enclosure installation. Thermal class B (130 °C) per IEC 60085 gives the winding insulation a 40 °C ambient rating with a 89 W power loss to dissipate inside the cabinet.

The 5.67 % impedance is a common choice for general-purpose harmonic mitigation and motor lead-length protection — enough to reduce harmonic distortion without dropping excessive voltage across the reactor under full load. Power loss of 89 W at rated load must be factored into the enclosure thermal design. In a sealed cabinet with multiple reactors or drives, that heat adds up — plan for forced ventilation or derating if ambient inside the panel exceeds 40 °C.

Frequently asked questions

What are the key electrical ratings of 4EP4001-3MS00?

Rated current 19.7 A, maximum current 21.9 A, rated voltage 400 V AC, frequency 50 Hz, inductance 0.0025 H, throttling factor 5.67 %, reactive power 12 500 var.

What is the physical size of 4EP4001-3MS00?

Width 0.219 m, height 0.179 m, depth 0.143 m. Protection class IP00 — open frame for enclosure mounting.