Skip to main content
Siemens 4EP4002-8DS00 — Line/Load Reactors

Siemens 4EP4002-8DS00 Commutating Choke, 400V 91A 3-Phase

MPN4EP4002-8DS00

Siemens 4EP4002-8DS00, commutating choke for converters, 3-phase, 400V AC, 91A max AC current, 0.25mH, IP00, flat-type terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP4002-8DS00 — Inductance & Impedance
ParameterValue
Rated inductance0.00025H
Relative inductive voltage drop4%

Identification

4EP4002-8DS00 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EP4002-8DS00 — Electrical
ParameterValue
Rated operating voltage400V
Rated current (AC)81.9A
Number of phases3
Current (AC), max.91A
Rated current (DC)111.5A
Voltage typeAC
Rated operating frequency50Hz
Peak current114A

Losses & Thermal

4EP4002-8DS00 — Losses & Thermal
ParameterValue
Power loss, coil (W)80W
Power loss, iron core (W)24W
Rated ambient temperature40°C

Approvals

4EP4002-8DS00 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP4002-8DS00 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Product details

The Siemens 4EP4002-8DS00 is a three-phase commutating choke for converter applications, rated at 400 V AC and 50 Hz. It handles a maximum AC current of 91 A and a peak current of 114 A, with an inductance of 0.25 mH and a relative inductive voltage drop of 4% at rated conditions.

What the ratings mean for your converter circuit

The 0.25 mH inductance and 4% relative inductive drop are sized to limit di/dt and reduce commutation notches on the line side of a converter. The 91 A AC maximum current (81.9 A continuous AC rated) and 111.5 A DC rated current tell you the choke can handle the ripple current in a DC link or AC line reactor application. With IP00 protection, this choke is an open-frame component meant for installation inside a panel or enclosure that provides the environmental seal. The flat-type terminals accept busbar or cable lugs — plan for a bolted connection, not a plug-in. Thermal class B (130 °C rise) and the combined power loss of 104 W (80 W coil + 24 W iron core) at 40 °C ambient mean the choke needs free air movement or forced ventilation inside the panel to stay within its rating.

Frequently asked questions

What are the physical dimensions of the 4EP4002-8DS00?

The choke measures 0.219 m wide, 0.179 m high, and 0.143 m deep. These dimensions are for the open-frame component itself, not including terminal lugs or mounting brackets.

MPN
4EP4002-8DS00