Skip to main content
Siemens 4EP4010-0LS00 — Line/Load Reactors

Siemens 4EP4010-0LS00 Mains Choke, 80A, 500V, 0.36mH

MPN4EP4010-0LS00

Siemens 4EP4010-0LS00 Netzdrossel, mains choke, 3-phase AC, 80A rated current, 500V rated voltage, 0.36mH inductance, IP00, screw-type terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP4010-0LS00 — Inductance & Impedance
ParameterValue
Rated inductance0.00036H
Relative inductive voltage drop3%

Identification

4EP4010-0LS00 — Identification
ParameterValue
Product designationNetzdrossel

Electrical

4EP4010-0LS00 — Electrical
ParameterValue
Rated operating voltage500, 500V
Number of phases3
Voltage typeAC
Rated operating frequency60 ... 50Hz

Losses & Thermal

4EP4010-0LS00 — Losses & Thermal
ParameterValue
Power loss, coil (W)50W
Power loss, iron core (W)32W
Rated ambient temperature40°C

Approvals

4EP4010-0LS00 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP4010-0LS00 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Product details

What it is and what it does

The Siemens 4EP4010-0LS00 is a three-phase mains choke (Netzdrossel) rated for 80 A continuous current at 500 V AC, 50/60 Hz. The 0.36 mH inductance limits harmonic distortion and inrush current on the line side of a drive or power supply — it's the component that keeps the upstream breaker from nuisance-tripping when a VFD's DC bus capacitors charge. Rated current is 80 A, with a rated value of 72 A under the listed conditions at 40 °C ambient. The 3% relative inductive voltage drop at rated current indicates the choke is sized for a typical line-reactor application.

Electrical and thermal ratings

Power loss splits into 50 W in the coil and 32 W in the iron core at rated conditions — 82 W total to dissipate inside the enclosure. Thermal class B per IEC 60085 means the insulation system is rated for 130 °C hot-spot, which is standard for industrial chokes and leaves headroom for moderate overloads. The IP00 protection class means the choke has no enclosure — it's a bare magnetic assembly intended for mounting inside a panel or cabinet where the environment is clean and dry. Screw-type terminals on the main circuit accept field wiring directly.

Mounting and integration

Dimensions are 0.219 m wide, 0.179 m high, and 0.143 m deep — roughly 219 × 179 × 143 mm. This is a panel-mount component; plan for the foot-print and clearance around the IP00 core for airflow. The 82 W heat load needs ventilation or forced air if the cabinet is sealed.

Frequently asked questions

Does 4EP4010-0LS00 have an enclosure or IP rating?

Protection class is IP00 — no enclosure. It is a bare choke intended for mounting inside a clean, dry electrical panel or cabinet.

MPN
4EP4010-0LS00