Skip to main content
Siemens 4EP4010-0NS10 — Line/Load Reactors

Siemens 4EP4010-0NS10 Mains Choke, 106A, 0.24 mH, 500 V AC

MPN4EP4010-0NS10

Siemens SENTRON 4EP4010-0NS10 mains choke (Netzdrossel), 106 A max / 95 A rated, 0.24 mH, 500 V AC, 50/60 Hz, IP00, EN 61558-2-20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP4010-0NS10 — Inductance & Impedance
ParameterValue
Rated inductance0.00024H
Relative inductive voltage drop2.7%

Identification

4EP4010-0NS10 — Identification
ParameterValue
Product designationNetzdrossel

Electrical

4EP4010-0NS10 — Electrical
ParameterValue
Rated operating voltage500, 500V
Number of phases3
Voltage typeAC
Rated operating frequency60 ... 50Hz

Losses & Thermal

4EP4010-0NS10 — Losses & Thermal
ParameterValue
Power loss, coil (W)50W
Power loss, iron core (W)31W
Rated ambient temperature40°C

Approvals

4EP4010-0NS10 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP4010-0NS10 — Mechanical
ParameterValue
Main-circuit connection typefree cable endings
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Product details

The Siemens 4EP4010-0NS10 is a three-phase mains choke (Netzdrossel) rated for 106 A maximum continuous current, 95 A nominal, with 0.24 mH inductance. It's designed for 500 V AC line voltage at 50/60 Hz and carries a 2.7% relative inductive voltage drop at rated conditions.

What the ratings mean for fit

The 106 A maximum / 95 A rated current tells you this choke is sized for a 95 A continuous motor or drive load, with headroom to 106 A for short-duration overloads. The 0.24 mH inductance at 500 V AC gives a typical line-reactor impedance that limits harmonic distortion and inrush current on variable-frequency drives or soft starters in that current class. IP00 means it's an open-frame component — no enclosure protection. It must be mounted inside a panel or cabinet that provides the environmental seal. The free cable endings (main circuit connection) require a terminal block or lug connection at the panel builder's end. Power dissipation breaks down as 50 W in the coil and 31 W in the iron core, totaling 81 W at rated load. That heat must be managed inside the enclosure — factor it into your thermal budget.

Integration notes

Mounting dimensions: 0.219 m wide × 0.179 m tall × 0.143 m deep. The open-frame construction (IP00) means it's panel-mounted, typically bolted to a mounting plate inside the enclosure. Free cable endings for the main circuit require field wiring to a terminal block or busbar. Thermal class B per IEC 60085 means the insulation system is rated for 130 °C maximum hot-spot temperature. Ambient temperature rating is 40 °C — derate current if ambient exceeds that.

MPN
4EP4010-0NS10