Skip to main content
Siemens 4EP4010-0NS30 — Line/Load Reactors

Siemens 4EP4010-0NS30 Mains Choke, 106A, 500V AC, 0.2 mH

MPN4EP4010-0NS30

Siemens Netzdrossel 4EP4010-0NS30, 3-phase mains choke, 106 A max (95.4 A rated), 500 V AC, 0.2 mH, IP00 open-frame.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP4010-0NS30 — Inductance & Impedance
ParameterValue
Rated inductance0.0002H
Relative inductive voltage drop2.7%

Identification

4EP4010-0NS30 — Identification
ParameterValue
Product designationNetzdrossel

Electrical

4EP4010-0NS30 — Electrical
ParameterValue
Rated operating voltage500, 500V
Number of phases3
Voltage typeAC
Rated operating frequency60 ... 50Hz

Losses & Thermal

4EP4010-0NS30 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C

Approvals

4EP4010-0NS30 — Approvals
ParameterValue
Thermal class (IEC 60085)B

Mechanical

4EP4010-0NS30 — Mechanical
ParameterValue
Main-circuit connection typefree cable endings
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Other specifications

4EP4010-0NS30 — Other specifications
ParameterValue
Rated value95.4A

Product details

The Siemens 4EP4010-0NS30 is a Netzdrossel (mains choke / line reactor) for 3-phase AC drives and power supplies. It carries a maximum continuous current of 106 A and a rated current of 95.4 A at 500 V AC, 50/60 Hz, with a rated inductance of 0.2 mH. The 2.7% relative inductive voltage drop at rated conditions means this choke provides moderate harmonic attenuation and current smoothing for a 3-phase line — sized for a drive or converter input where you need to limit di/dt and reduce reflected-wave stress on the DC bus.

The 4EP4010-0NS30 is an open-frame (IP00) component — no enclosure, no finger-safe terminals. Mounting dimensions are 0.219 m wide, 0.179 m high, 0.143 m deep. The main circuit connects via free cable endings, so plan for a junction box or terminal block within the panel. Thermal class B (130 °C winding rise per IEC 60085) and a 40 °C ambient rating; derate above that. This is not a DIN-rail snap-on part — it bolts into the cabinet floor or a sub-panel, with clearance for airflow and creepage.

Frequently asked questions

What are the key electrical ratings of the 4EP4010-0NS30?

Maximum continuous current is 106 A; rated current is 95.4 A at 500 V AC, 50/60 Hz, 3-phase. Inductance is 0.2 mH with a 2.7% relative inductive voltage drop at rated conditions. The choke is designed per EN 61558-2-20.

How do I get pricing and availability for 4EP4010-0NS30?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and lead time — availability is confirmed at quote time.

What compliance documentation does Siemens provide for 4EP4010-0NS30?

The choke is designed to EN 61558-2-20 for safety of transformers, reactors, and similar equipment. The manufacturer's standard declaration includes CE marking for the European market. Specific RoHS/REACH declarations are available upon request through the RFQ process.

MPN
4EP4010-0NS30