Skip to main content
Siemens 4EP4010-0TS01 — Line/Load Reactors

Siemens 4EP4010-0TS01 Reactor, 3-Phase, 400V, 15.8A, 3.2mH

MPN4EP4010-0TS01

Siemens 4EP4010-0TS01, 3-phase line reactor, 400V AC, 15.8A rated current, 3.2mH inductance, IP00, screw terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EP4010-0TS01 — Inductance & Impedance
ParameterValue
Rated inductance0.0032H

Identification

4EP4010-0TS01 — Identification
ParameterValue
Product designationreactor

Electrical

4EP4010-0TS01 — Electrical
ParameterValue
Number of phases3
Voltage typeAC

Losses & Thermal

4EP4010-0TS01 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C

Approvals

4EP4010-0TS01 — Approvals
ParameterValue
Thermal class (IEC 60085)F

Mechanical

4EP4010-0TS01 — Mechanical
ParameterValue
Main-circuit connection typescrew-type terminals
IP protection ratingIP00
Height0.179m
Width0.219m
Depth0.143m

Other specifications

4EP4010-0TS01 — Other specifications
ParameterValue
Rated value15.8A

Product details

What it is and what it does

The Siemens 4EP4010-0TS01 is a 3-phase line reactor (choke) rated for 400 V AC, 15.8 A continuous current, with 3.2 mH inductance per phase. It's designed to limit harmonic distortion, reduce voltage notching, and protect drives and other power electronics from line-side transients. Rated for a maximum current of 17.5 A at 100 Hz, the reactor is built to IEC 61558-2-20 and carries thermal class F (155 °C) insulation per IEC 60085. The IP00 enclosure means it's an open-frame component intended for installation inside a cabinet or panel — not for washdown or outdoor exposure. Connection is via screw-type terminals on the main circuit, sized for the 15.8 A nominal load. At 0.143 m deep, 0.219 m wide, and 0.179 m tall, it fits a standard panel footprint but needs clearance around the open core for heat dissipation.

Sourcing and lifecycle reality

No official successor has been published. If your BOM calls for this exact order code, the safest route is to quote against the 4EP4010-0TS01 rather than substitute — the 3.2 mH inductance and 15.8 A rating are specific to this variant.

Integration notes

Mount inside a panel with adequate ventilation — the open-frame IP00 design relies on cabinet airflow for cooling. The 0.143 m depth fits a standard 200 mm deep enclosure, but leave at least 50 mm clearance above and below the core for natural convection. Screw terminals accept common lug sizes for 15.8 A circuit wiring. Torque to the manufacturer's specification for the terminal block (not listed here — verify on the nameplate or installation instructions).

Frequently asked questions

Where can I buy 4EP4010-0TS01 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the rated current and inductance of 4EP4010-0TS01?

Rated continuous current is 15.8 A with a maximum of 17.5 A at 100 Hz. Inductance per phase is 3.2 mH at 400 V AC, 3-phase.

What compliance documentation is available for 4EP4010-0TS01?

The reactor is designed to IEC 61558-2-20 and carries thermal class F insulation per IEC 60085. Specific RoHS, REACH, or UL documentation should be requested at quote time — the evidence does not list those marks directly.

MPN