Siemens 4EU2422-0EA00-4BA0 — Line/Load Reactors

Siemens 4EU2422-0EA00-4BA0 Commutating Choke, 90A Rated, 0.2

MPN4EU2422-0EA00-4BA0

Siemens 4EU2422-0EA00-4BA0 commutating choke for converter, 3-phase, 460V AC, rated 90A (max 100A), 0.29mH, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU2422-0EA00-4BA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00029H
Relative inductive voltage drop0%
4EU2422-0EA00-4BA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU2422-0EA00-4BA0 — Electrical
ParameterValue
Rated operating voltage0, 460V
Number of phases3
Rated current (DC)122.5A
Voltage typeAC
Rated operating frequency0 ... 60Hz
4EU2422-0EA00-4BA0 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C
4EU2422-0EA00-4BA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU2422-0EA00-4BA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.225m
Depth0.136m

Product details

The Siemens 4EU2422-0EA00-4BA0 is a commutating choke (line reactor) for converter applications — 3-phase, 460V AC, rated 90A continuous with a 100A maximum. The 0.29mH inductance limits current rise and harmonic distortion on the input side of a variable-frequency drive or DC drive converter. Thermal class H insulation (180°C rated) means it handles the heat buildup in a closed panel without derating prematurely.

Where it fits — panel and mounting

IP00 means no enclosure — this choke mounts inside a cabinet, not in a washdown area. The flat-type terminals accept busbar or cable lugs, not spring-cage or screw-clamp wire ends. Footprint: 0.225m wide × 0.21m tall × 0.136m deep. That depth is the body depth, not including terminal protrusion — allow 20-30mm extra for lug overhang when laying out the gland plate. No DIN-rail clip; it bolts directly to the panel backplate.

The 100A maximum is the short-time overload — do not size a 90A motor and expect the choke to carry 100A indefinitely. The DC rated value of 122.5A applies if the choke is used on the DC link side of a converter, not the AC input. The 0% relative inductive drop means the voltage drop across the choke at rated current is negligible for most line-regulator calculations — the 4% impedance figure in the description is the more practical number for sizing voltage drop and harmonic attenuation.

Frequently asked questions

What are the key specifications of 4EU2422-0EA00-4BA0?

3-phase commutating choke, 460V AC, rated 90A continuous (100A max), 0.29mH inductance, IP00 enclosure, flat-type terminals. Thermal class H insulation. Dimensions: 0.225m wide × 0.21m tall × 0.136m deep.

Where can I buy 4EU2422-0EA00-4BA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
4EU2422-0EA00-4BA0