Skip to main content
Siemens 4EU2422-8AA00-0AA0 — Line/Load Reactors

Siemens 4EU2422-8AA00-0AA0 Commutating Choke, 3-Phase, 500V,

MPN4EU2422-8AA00-0AA0

Siemens 4EU2422-8AA00-0AA0, commutating choke for converter, 3-phase, 500V AC, 80A AC max, 0.36 mH, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

4EU2422-8AA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00036H
Relative inductive voltage drop4%
4EU2422-8AA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU2422-8AA00-0AA0 — Electrical
ParameterValue
Rated operating voltage500V
Rated current (AC)72A
Number of phases3
Current (AC), max.80A
Rated current (DC)98A
Voltage typeAC
Rated operating frequency50Hz
Peak current100A
4EU2422-8AA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)120W
Power loss, iron core (W)42W
Rated ambient temperature40°C
4EU2422-8AA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU2422-8AA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.225m
Depth0.136m

Product details

The Siemens 4EU2422-8AA00-0AA0 is a 3-phase commutating choke for converter applications, rated 500 V AC with an AC maximum current of 80 A and a DC rated current of 98 A. The IP00 enclosure means it is an open-frame component for cabinet mounting, not standalone outdoor use.

The 80 A AC maximum current (at 50 Hz) and 72 A AC rated current define the continuous thermal limit under sinusoidal conditions; the 98 A DC rated value covers the DC-link current the choke sees in a typical 6-pulse converter. Thermal class H (180 °C hot-spot) per IEC 60085 means the winding insulation can handle sustained high temperatures — relevant if the cabinet ambient hits 40 °C (the rated ambient temperature) and the choke is running near its full current. The 120 W coil loss plus 42 W iron core loss total 162 W of heat to vent inside the panel; factor that into your enclosure's thermal budget. Flat-type terminals (bus-bar style) accept lugs or copper bars, not wire ferrules — plan the main circuit connections accordingly.

Physical integration

Dimensions are 0.225 m wide, 0.21 m high, and 0.136 m deep — a substantial block that needs dedicated mounting space in the panel, not a DIN-rail clip-on. The IP00 protection class means no enclosure of its own; mount it where live parts are inaccessible during operation, or provide supplementary guarding. The flat-type main circuit terminals are designed for bolted connections; torque them per Siemens' recommended values (not listed here, but standard for M8 or M10 bus-bar hardware).

MPN
4EU2422-8AA00-0AA0