Siemens 4EU2451-2UA00-0A — Line/Load Reactors

Siemens 4EU2451-2UA00-0A Mains Choke, 160 A, 3-Phase, 400/48

MPN4EU2451-2UA00-0A

Siemens 4EU2451-2UA00-0A mains choke (Netzdrossel f. FU), 3-phase, 400/480 VAC, 160 A max / 144 A rated, 0.088 mH, 2% voltage drop, IP00, Class H, flat-type terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU2451-2UA00-0A — Inductance & Impedance
ParameterValue
Rated inductance0.000088H
Relative inductive voltage drop2%

Identification

4EU2451-2UA00-0A — Identification
ParameterValue
Product designationNetzdrossel f. FU

Electrical

4EU2451-2UA00-0A — Electrical
ParameterValue
Rated operating voltage400, 480V
Number of phases3
Voltage typeAC
Rated operating frequency50 ... 60Hz

Losses & Thermal

4EU2451-2UA00-0A — Losses & Thermal
ParameterValue
Power loss, coil (W)120W
Rated ambient temperature40°C

Approvals

4EU2451-2UA00-0A — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU2451-2UA00-0A — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.225m
Depth0.147m

Product details

What it is and what it does

The Siemens 4EU2451-2UA00-0A is a three-phase mains choke (line reactor) designed for installation ahead of a variable-frequency drive (VFD). It smooths the input current, limits harmonic distortion, and protects the drive's DC bus from line transients. Rated for 400/480 VAC at 50/60 Hz, it carries a maximum continuous current of 160 A and a rated current of 144 A — the figure you use for sizing against your motor load. The 0.000088 H (88 µH) inductance produces a 2% relative inductive voltage drop at rated current and frequency. That 2% figure is the design target: it's enough to suppress harmonics without dropping excessive voltage across the choke under load.

Mounting and integration

This is an IP00 open-frame choke — no enclosure, no finger-safe covers. It's intended for installation inside a panel where the live bus bars and flat-type terminals are isolated by the cabinet door or a separate barrier. Dimensions are 0.225 m wide, 0.21 m high, and 0.147 m deep; plan your gland plate and DIN-rail layout accordingly, though the choke itself bolts to a mounting plate rather than snapping onto a rail. The main circuit connects via flat-type terminals — expect bus-bar or cable-lug terminations, not spring-cage or screw-clamp. Verify your lug width and bolt size against the terminal opening before panel assembly.

Thermal and insulation class

Rated for a 40 °C ambient, the coil dissipates 120 W at full load. Class H insulation (180 °C rated) gives a generous thermal margin — the choke can run hot without degrading the winding insulation, which matters in a crowded panel where airflow is restricted.

Frequently asked questions

What is the 4EU2451-2UA00-0A used for?

It is a three-phase mains choke (line reactor) installed ahead of a variable-frequency drive to limit harmonic distortion, smooth input current, and protect the drive's DC bus from line transients.

What are the key ratings of the 4EU2451-2UA00-0A?

Maximum continuous current is 160 A, rated current is 144 A, operating voltage is 400/480 VAC at 50/60 Hz, inductance is 0.000088 H, and the relative inductive voltage drop is 2%.

Where can I buy the 4EU2451-2UA00-0A?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing.