Skip to main content
Siemens 4EU2452-0AD00-4BA0 — Line/Load Reactors

SIDAC 4EU2452-0AD00-4BA0 Output Reactor, 111A, 4000Hz, 3-Pha

MPN4EU2452-0AD00-4BA0

SIDAC output reactor, 3-phase AC, 111A max current, 4000Hz rated frequency, IP00, thermal class H, flat-type terminals, 0.07mH inductance.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU2452-0AD00-4BA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00007H
4EU2452-0AD00-4BA0 — Identification
ParameterValue
Product designationoutput reactor
4EU2452-0AD00-4BA0 — Electrical
ParameterValue
Number of phases3
Voltage typeAC
4EU2452-0AD00-4BA0 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C
4EU2452-0AD00-4BA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU2452-0AD00-4BA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.22m
Depth0.13m
4EU2452-0AD00-4BA0 — Other specifications
ParameterValue
Rated value4 000Hz

Product details

The SIDAC 4EU2452-0AD00-4BA0 is a 3-phase AC output reactor (output choke) rated for a maximum continuous current of 111A at a rated frequency of 4000Hz, with an inductance of 0.07mH. It sits between the drive output and the motor cable to limit the rate of voltage rise (dV/dt) and reduce capacitive charging currents in long cable runs — critical on a line where reflected-wave overvoltage can punch through motor insulation. The 111A rating means it handles a motor load drawing up to that current without saturating the core; the 4000Hz switching frequency matches modern IGBT drives running fast carrier frequencies, so the reactor's impedance stays effective at the switching harmonics that cause the most motor stress.

Thermal and environmental limits

Rated for a 40°C ambient with thermal class H insulation (180°C hot-spot) per IEC 60085. The IP00 enclosure means it is an open-frame component — it needs a clean, dry panel or cabinet; no washdown, no dust. The flat-type terminals accept busbar or cable lugs, typical for the current level. Dimensions: 0.22m wide, 0.21m high, 0.13m deep — plan panel space accordingly.

Frequently asked questions

Where can I buy 4EU2452-0AD00-4BA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 4EU2452-0AD00-4BA0?

It is a 3-phase AC output reactor rated for 111A maximum current, 4000Hz rated frequency, 0.07mH inductance, IP00 enclosure, thermal class H, and 40°C ambient temperature.

MPN
4EU2452-0AD00-4BA0