Skip to main content
Siemens 4EU2452-5UA00-0AA0 — Line/Load Reactors

Siemens 4EU2452-5UA00-0AA0 Mains Choke, 3-Phase, 63A, 0.58 m

MPN4EU2452-5UA00-0AA0

Siemens 4EU2452-5UA00-0AA0 mains choke (line reactor) for variable-frequency drives, 3-phase, 500 V AC, 63 A max / 56.7 A rated, 0.58 mH, 4 % voltage drop, IP00, thermal class H, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU2452-5UA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00058H
Relative inductive voltage drop4%
4EU2452-5UA00-0AA0 — Identification
ParameterValue
Product designationNetzdrossel f. FU
4EU2452-5UA00-0AA0 — Electrical
ParameterValue
Rated operating voltage500V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz
4EU2452-5UA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)125W
Power loss, iron core (W)27W
Rated ambient temperature40°C
4EU2452-5UA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU2452-5UA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.225m
Depth0.147m

Product details

The Siemens 4EU2452-5UA00-0AA0 is a three-phase mains choke (line reactor) designed to sit between the supply and a variable-frequency drive. It smooths current harmonics, limits inrush, and protects the drive's DC-link capacitors from line transients. Rated 500 V AC, 50 Hz, with a maximum continuous current of 63 A and a rated current of 56.7 A, it handles the full load of a 30–37 kW drive class depending on duty. The 0.58 mH inductance and 4 % relative inductive voltage drop are typical for a 4 % impedance reactor — a common choice for reducing harmonic distortion without excessive voltage sag under load.

Fit and mounting reality

Dimensions are 0.225 m wide, 0.21 m tall, and 0.147 m deep. The flat-type terminals accept busbar or cable lugs; expect to land power wiring with ring or fork terminals. Thermal class H insulation (180 °C rated) means the choke can run hot without degrading the winding varnish, but the 125 W coil loss plus 27 W iron loss (152 W total at rated load) must be vented — forced air or a properly sized enclosure is recommended if ambient hits 40 °C.

Frequently asked questions

What is the voltage drop of this choke?

The relative inductive voltage drop is 4 % at rated current and frequency — a standard value for line reactors used to reduce harmonics without excessive voltage sag.

Where can I buy 4EU2452-5UA00-0AA0?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and lead time.

MPN
4EU2452-5UA00-0AA0