Siemens 4EU2522-2AA00-0AA0 — Line/Load Reactors

Siemens 4EU2522-2AA00-0AA0 Commutating Choke, 160A, 400V, 0.

MPN4EU2522-2AA00-0AA0

Siemens SENTRON series commutating choke, 3-phase, 400V AC, 160A max / 144A rated, 0.18mH, IP00, thermal class H, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU2522-2AA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00018H
Relative inductive voltage drop4%
4EU2522-2AA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU2522-2AA00-0AA0 — Electrical
ParameterValue
Rated operating voltage400V
Number of phases3
Rated current (DC)196A
Voltage typeAC
Rated operating frequency50Hz
Peak current175A
4EU2522-2AA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)131W
Power loss, iron core (W)64W
Rated ambient temperature40°C
4EU2522-2AA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU2522-2AA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.21m
Width0.225m
Depth0.16m

Product details

What This Choke Does in a Drive System

The Siemens 4EU2522-2AA00-0AA0 is a 3-phase commutating choke (also called a line reactor or converter choke) rated for 400V AC systems at 50 Hz. Its 0.18 mH inductance limits current rise during converter switching events, protecting the rectifier diodes and smoothing the DC bus ripple. The 160 A maximum continuous rating and 144 A nominal rating tell you the sustained load it can carry at 40 °C ambient — size your motor drive or converter load against the 144 A figure, not the peak. The 4% relative inductive voltage drop (uk) at rated current and frequency is the impedance you need for coordination studies — it determines how much voltage sag the choke introduces under load and how it contributes to fault current limiting.

Thermal and Mounting Reality — IP00 Means Open Frame

IP00 protection class means this choke has no enclosure — it's an open-frame component for mounting inside a panel or cabinet. The 131 W coil loss plus 64 W iron core loss (195 W total at rated conditions) must be ventilated out of the enclosure; don't bury it in a sealed box without forced airflow. Thermal class H insulation (180 °C hot-spot rating per IEC 60085) gives headroom for high-ambient environments, but the 40 °C ambient rating is the design point for the 144 A figure — derate above that.

MPN