Skip to main content
Siemens 4EU2732-5MA08-0AA0 — Line/Load Reactors

Siemens 4EU2732-5MA08-0AA0 SIDAC Filter Reactor, 80.3A, 400V

MPN4EU2732-5MA08-0AA0

Siemens SIDAC 4EU2732-5MA08-0AA0, 3-phase filter reactor, 400V AC, 80.3A max, 50Hz, 7% throttling, IP00, flat/screw terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU2732-5MA08-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00077H
Relative throttling factor7%
Filter resonant frequency189Hz
Rated reactive power (filter bank)50 000var

Identification

4EU2732-5MA08-0AA0 — Identification
ParameterValue
Product designationfilter reactor

Electrical

4EU2732-5MA08-0AA0 — Electrical
ParameterValue
Rated operating voltage400V
Rated current (AC)72.3A
Number of phases3
Current (AC), max.80.3A
Voltage typeAC
Rated operating frequency50Hz

Losses & Thermal

4EU2732-5MA08-0AA0 — Losses & Thermal
ParameterValue
Total power loss (W)223W
Rated ambient temperature40°C

Approvals

4EU2732-5MA08-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU2732-5MA08-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector / screw-type terminals
IP protection ratingIP00
Height0.248m
Width0.27m
Depth0.187m

Product details

What it is and where it fits

The Siemens 4EU2732-5MA08-0AA0 is a SIDAC-branded 3-phase filter reactor rated for 400V AC at 50Hz. It carries a maximum AC current of 80.3A and an operating current of 72.3A, with a 7% relative throttling factor and a resonant frequency of 189Hz. The 223W power loss at rated load means it needs ventilation clearance in the panel — IP00 rating confirms it is an open-frame component for cabinet mounting only, not for washdown or outdoor exposure. Thermal class H (180°C) insulation gives headroom for elevated ambient temperatures up to 40°C.

What the ratings mean for your panel

The 7% throttling factor means this reactor limits harmonic currents and reduces voltage notching on the line side of a variable-frequency drive or soft starter — a common choice for 6-pulse rectifier front ends. The 189Hz resonant frequency is well above the 50Hz fundamental, so it does not create a low-impedance trap at line frequency. At 72.3A operating current and 50 kvar reactive power, it is sized for drives in the 37–45 kW range on a 400V supply. The flat connector / screw-type terminals accept busbar or cable lugs; plan for the 0.187m depth and 0.27m width when laying out the sub-panel. IP00 means the reactor must be inside a grounded enclosure — no exposed live parts in the cabinet.

Frequently asked questions

How do I get current pricing and availability for 4EU2732-5MA08-0AA0?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; current pricing and lead time are confirmed at quote time.

What is 4EU2732-5MA08-0AA0's listed depth (0.187m) on this component line?

The depth is 0.187m. Combined with a width of 0.27m and height of 0.248m, it requires a panel footprint of roughly 0.27m by 0.248m with at least 0.187m of clearance behind the mounting surface.

What compliance documentation does this brand provide for 4EU2732-5MA08-0AA0?

The evidence does not list specific compliance certificates (RoHS, REACH, UL, IEC) for this order code. The reactor is designed to EN 61558-2-20 per the description, which covers chokes. For project documentation, request the manufacturer's declaration at quote time.

MPN
4EU2732-5MA08-0AA0