Skip to main content
Siemens 4EU2732-6MA08-0AA0 — Line/Load Reactors

Siemens SIDAC 4EU2732-6MA08-0AA0 Filter Reactor, 63.2A, 400V

MPN4EU2732-6MA08-0AA0

Siemens SIDAC series, filter reactor, 3-phase, 63.2 A rated / 70.2 A max, 400 V AC, 50 Hz, 40 kvar, IP00, flat/screw terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU2732-6MA08-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00077H
Relative throttling factor5.67%
Filter resonant frequency210Hz
Rated reactive power (filter bank)40 000var

Identification

4EU2732-6MA08-0AA0 — Identification
ParameterValue
Product designationfilter reactor

Electrical

4EU2732-6MA08-0AA0 — Electrical
ParameterValue
Rated operating voltage400V
Number of phases3
Voltage typeAC
Rated operating frequency50Hz

Losses & Thermal

4EU2732-6MA08-0AA0 — Losses & Thermal
ParameterValue
Total power loss (W)221W
Rated ambient temperature40°C

Approvals

4EU2732-6MA08-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU2732-6MA08-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector / screw-type terminals
IP protection ratingIP00
Height0.248m
Width0.27m
Depth0.187m

Product details

What this part is and what it does

The Siemens SIDAC 4EU2732-6MA08-0AA0 is a 3-phase filter reactor rated for 63.2 A continuous with a maximum current of 70.2 A, designed for 400 V AC, 50 Hz line applications. It provides 40 kvar of reactive power compensation and a relative throttling factor of 5.67%.

Key ratings and what they mean for fit

The 63.2 A rated current (70.2 A maximum) sets the continuous load the reactor can carry without saturating or overheating — match this to the drive or load's nameplate current, not the breaker size. The 5.67% impedance (relative throttling factor) is a standard value for line reactors: it drops enough voltage to smooth current and reduce harmonic distortion without starving the drive of voltage under load. The 40 kvar reactive power rating tells you the reactor's contribution to power-factor correction at rated conditions. Thermal class H insulation (IEC 60085) means the winding can sustain 180 °C hot-spot temperature — typical for industrial drives in warm cabinets where standard class B or F would derate.

Frequently asked questions

Where can I buy 4EU2732-6MA08-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ. Submit a request for quote (RFQ) through this listing; availability and current pricing are confirmed at quote time. No stock count or price is published here.

MPN
4EU2732-6MA08-0AA0