Skip to main content
Siemens 4EU3022-0EK00-0BA0 — Line/Load Reactors

Siemens 4EU3022-0EK00-0BA0 Commutating Choke, 270A, 480V, 3-

MPN4EU3022-0EK00-0BA0

Siemens commutating choke for converters, 4EU3022-0EK00-0BA0, 3-phase, 480V AC, rated 270A, max 300A, 0.098 mH, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3022-0EK00-0BA0 — Inductance & Impedance
ParameterValue
Rated inductance0.000098H
Relative inductive voltage drop4%
4EU3022-0EK00-0BA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU3022-0EK00-0BA0 — Electrical
ParameterValue
Rated operating voltage480, 480V
Number of phases3
Voltage typeAC
Rated operating frequency50 ... 60Hz
4EU3022-0EK00-0BA0 — Losses & Thermal
ParameterValue
Rated ambient temperature50°C
4EU3022-0EK00-0BA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3022-0EK00-0BA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.269m
Width0.3m
Depth0.221m
4EU3022-0EK00-0BA0 — Other specifications
ParameterValue
Rated value270A

Product details

The Siemens 4EU3022-0EK00-0BA0 is a 3-phase commutating choke (also called a line reactor) for converter applications, rated 270 A continuous with a 300 A maximum, at 480 V AC, 50/60 Hz. The 0.098 mH inductance and 4% relative inductive voltage drop are sized to limit current rise and reduce harmonics on the converter's input or DC link — common in variable-frequency drive and rectifier front ends.

The 270 A rated current (I LN) and 300 A maximum (Ithmax) tell you this choke is sized for a 270 A continuous load with headroom to 300 A — typical for a 200–250 hp drive at 480 V. The 4% voltage drop at rated current is the standard impedance for most drive line reactors; it limits fault current and smooths the DC bus without excessive voltage sag. The 0.098 mH inductance is fixed — no taps — so verify your drive's minimum line impedance requirement before specifying. IP00 means no enclosure — this is an open-frame component intended for a ventilated cabinet or panel. The flat-type terminals accept bus bar or large cable lugs, not spring-cage or screw-clamp connectors. Thermal class H insulation means the winding can handle a 180 °C hot-spot temperature, so it survives the heat inside a crowded converter cabinet.

Mounts in a drive panel or converter cabinet — the 0.3 m width, 0.269 m height, and 0.221 m depth (–) need a clear footprint and ventilation around the IP00 core. Common on the input side of a 480 V three-phase drive to reduce harmonic distortion and protect the rectifier from line spikes, or on the DC link for current smoothing.

Frequently asked questions

What are the key ratings of this commutating choke?

Rated 270 A continuous, 300 A maximum, 480 V AC, 3-phase, 0.098 mH inductance, 4% voltage drop, IP00, thermal class H, flat-type terminals.

Where can I buy 4EU3022-0EK00-0BA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 4EU3022-0EK00-0BA0 drop into a panel designed around 3RV6011-0CA10?

No — the 3RV6011-0CA10 is a motor-protective circuit breaker (SIRIUS S00, 0.25 A, DIN-rail mount), while this is a 270 A open-frame choke with flat terminals. They serve entirely different functions and footprints; no direct interchange.

MPN
4EU3022-0EK00-0BA0