Siemens 4EU3022-5CA00-0AA0 Commutating Choke, 200A, 3-Phase

MPN4EU3022-5CA00-0AA0

Siemens 4EU3022-5CA00-0AA0, commutating choke for converter, 3-phase, 200A max, 180A rated, 750V, 0.28mH, IP00, flat-type terminal.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU3022-5CA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00028H
Relative inductive voltage drop4%

Identification

4EU3022-5CA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EU3022-5CA00-0AA0 — Electrical
ParameterValue
Rated operating voltage750, 750V
Number of phases3
Rated current (DC)245A
Voltage typeAC
Rated operating frequency60 ... 50Hz

Losses & Thermal

4EU3022-5CA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)220W
Power loss, iron core (W)160W
Rated ambient temperature40°C

Approvals

4EU3022-5CA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU3022-5CA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.269m
Width0.3m
Depth0.211m

Product details

The Siemens 4EU3022-5CA00-0AA0 is a 3-phase commutating choke (line reactor) for converter applications, rated for a maximum continuous current of 200 A and a nominal current of 180 A at 50/60 Hz. It's built for a 750 V AC operating voltage with an inductance of 0.28 mH and a relative inductive voltage drop of 4% at rated conditions — that 4% drop is the key number for sizing the DC bus or AC line impedance on a drive input. The IP00 enclosure means it's an open-frame component — no splash or dust protection — so it mounts inside a cabinet, not out on the floor where coolant or washdown hits it.

The thermal class is H per IEC 60085, which means the insulation system can handle a 180 °C hot-spot temperature — important if you're pushing the full 220 W coil loss plus 160 W iron loss in a warm cabinet.

Connections are flat-type terminals for the main current circuit — no screw-clamp or ring-lug here. Plan for busbar or flat-cable termination when laying out the panel. Dimensions are 0.3 m wide by 0.269 m tall by 0.211 m deep — it takes up a fair chunk of panel real estate, so check your enclosure depth and side clearance before committing the backplate layout.

Frequently asked questions

Where can I buy 4EU3022-5CA00-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What are the key ratings for 4EU3022-5CA00-0AA0?

It's a 3-phase AC commutating choke rated for 200 A maximum continuous current, 180 A nominal, at 750 V operating voltage and 50/60 Hz. Inductance is 0.28 mH with a 4% voltage drop at rated current.

What compliance documentation does this choke carry?

The design follows EN 61558 for power transformers and chokes. Thermal class H per IEC 60085. Specific RoHS/REACH/UL declarations should be confirmed at quote time — the evidence doesn't list those certs directly.

MPN