Skip to main content
Siemens 4EU3022-6CA00-0AA0 — Line/Load Reactors

Siemens 4EU3022-6CA00-0AA0 Commutating Choke, 224A, 0.25mH

MPN4EU3022-6CA00-0AA0

Siemens 4EU3022-6CA00-0AA0 commutating choke for converter, 3-phase, 750V AC, 224A max / 201.6A rated, 0.25mH, IP00, flat-type terminals.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU3022-6CA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00025H
Relative inductive voltage drop4%

Identification

4EU3022-6CA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EU3022-6CA00-0AA0 — Electrical
ParameterValue
Rated operating voltage0, 750V
Number of phases3
Rated current (DC)274.5A
Voltage typeAC
Rated operating frequency0 ... 50Hz

Losses & Thermal

4EU3022-6CA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)208W
Power loss, iron core (W)151W
Rated ambient temperature40°C

Approvals

4EU3022-6CA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU3022-6CA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.269m
Width0.3m
Depth0.211m

Product details

What it is and what it does

The Siemens 4EU3022-6CA00-0AA0 is a 3-phase commutating choke — a line reactor — designed for the DC link of a converter or drive. It smooths current ripple and limits di/dt during commutation, which protects the converter's semiconductor switches and reduces harmonic distortion feeding back to the line. Rated for a continuous current of 201.6 A (224 A maximum) at 750 V AC, 50 Hz, with an inductance of 0.00025 H. The 4% relative inductive voltage drop at rated current governs voltage headroom across the choke.

Where it goes and how it mounts

IP00 open-frame construction means this choke has no enclosure — it mounts inside a panel or cabinet where the ambient stays clean and dry. The flat-type terminals accept bus-bar or heavy cable lugs; plan for bolted connections, not spring-clamp wiring. Footprint measures 0.3 m wide by 0.211 m deep by 0.269 m tall. Combined copper and iron losses total 208 W plus 151 W.

Thermal class and operating conditions

Rated for a 40 °C ambient with Class H insulation per IEC 60085 — that's a 180 °C hot-spot limit, so it can handle sustained overloads and high ambient temperatures inside a crowded panel without derating prematurely. The DC-rated current is 274.5 A — useful if you're applying it in a DC-link circuit rather than the AC line side. The 0–50 Hz operating frequency covers standard 50 Hz mains and variable-frequency drive output up to 50 Hz.

MPN
4EU3022-6CA00-0AA0