Skip to main content
Siemens 4EU3052-0AM10-4BA0 — Line/Load Reactors

Siemens SIDAC 4EU3052-0AM10-4BA0 Output Reactor, 88A, 5820 H

MPN4EU3052-0AM10-4BA0

Siemens SIDAC 4EU3052-0AM10-4BA0 output reactor, 3-phase AC, 88 A maximum current, 5820 Hz rated frequency, IP00, flat-type terminals.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3052-0AM10-4BA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00014H
4EU3052-0AM10-4BA0 — Identification
ParameterValue
Product designationoutput reactor
4EU3052-0AM10-4BA0 — Electrical
ParameterValue
Number of phases3
Voltage typeAC
4EU3052-0AM10-4BA0 — Losses & Thermal
ParameterValue
Rated ambient temperature40°C
4EU3052-0AM10-4BA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3052-0AM10-4BA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.26m
Width0.3m
Depth0.21m
4EU3052-0AM10-4BA0 — Other specifications
ParameterValue
Rated value5 820Hz

Product details

What this output reactor does

The Siemens SIDAC 4EU3052-0AM10-4BA0 is a 3-phase AC output reactor rated for 88 A maximum current and a switching frequency of 5820 Hz. It is designed to sit between a variable-frequency drive and the motor, smoothing the voltage spikes and limiting the rate of voltage rise (dV/dt) that long cable runs or fast-switching IGBTs can produce. The 0.14 mH inductance per phase (0.00014 H) and 26.8 % impedance (UK) are sized for a 500 V line, with a 40 °C ambient and Class H insulation (180 °C thermal class per IEC 60085).

The enclosure measures 0.3 m wide by 0.26 m tall by 0.21 m deep and carries an IP00 protection class — no enclosure, so it must be mounted inside a panel or cabinet that provides the environmental seal. Main circuit connections are via flat-type terminals, typical for bolted bus-bar or lug-style wiring.

Frequently asked questions

Where can I buy 4EU3052-0AM10-4BA0 and get a price?

This part is sourced to order against an RFQ through independent distribution channels. Submit a request with your target quantity and delivery window; availability and current pricing are confirmed at quote time.

What are the key ratings of 4EU3052-0AM10-4BA0?

It is a 3-phase AC output reactor rated for 88 A maximum current, 5820 Hz switching frequency, 0.14 mH inductance, and 500 V line voltage. The insulation is Class H (180 °C) per IEC 60085, and the ambient temperature rating is 40 °C. Protection class is IP00.

What is the physical size of 4EU3052-0AM10-4BA0?

The enclosure dimensions are 0.3 m wide by 0.26 m tall by 0.21 m deep.

MPN
4EU3052-0AM10-4BA0