Skip to main content
Siemens 4EU3622-0DA00-0AA0 — Line/Load Reactors

Siemens 4EU3622-0DA00-0AA0 Commutating Choke, 315A, 3-Phase

MPN4EU3622-0DA00-0AA0

Siemens 4EU3622-0DA00-0AA0 commutating choke for converter, 3-phase, 315A max, 284A rated, 690V AC, IP00, flat-type terminal.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

4EU3622-0DA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.00012H
Relative inductive voltage drop4%
4EU3622-0DA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter
4EU3622-0DA00-0AA0 — Electrical
ParameterValue
Rated operating voltage690, 690V
Number of phases3
Rated current (DC)386A
Voltage typeAC
Rated operating frequency60 ... 50Hz
Peak current394A
4EU3622-0DA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)320W
Power loss, iron core (W)180W
Rated ambient temperature40°C
4EU3622-0DA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H
4EU3622-0DA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.227m

Product details

What this choke does in a drive line

The Siemens 4EU3622-0DA00-0AA0 is a 3-phase commutating choke for converter applications, rated 315 A maximum continuous current and 284 A nominal current at 50/60 Hz. It limits the rate of rise of current during thyristor or IGBT commutation, reducing harmonic stress on the DC link and smoothing the current waveform. Rated for 690 V AC operating voltage, it handles the line side of most 400 V and 690 V class drives. The 394 A peak current rating covers short-duration overloads during motor starting or load transients. Thermal class H insulation (180 °C hot-spot) means the choke can run hot in a sealed cabinet without derating, as long as the ambient stays at or below 40 °C.

IP00 protection class means the choke has no enclosure. Dimensions are 0.35 m wide by 0.321 m tall by 0.227 m deep. Flat-type terminals accept busbar or cable lugs. Total power loss is 500 W (320 W in the coil plus 180 W in the iron core). That heat must be vented or conducted out of the enclosure — factor it into your cabinet thermal budget, especially if the drive and choke share a compartment.

Frequently asked questions

Will 4EU3622-0DA00-0AA0 drop into a panel specified around 5SQ2270-2YA04?

No — those are completely different component classes. The 5SQ2270-2YA04 is a SENTRON miniature circuit breaker (2-pole, 4 A, C-curve, DIN-rail mount, IP20). The 4EU3622-0DA00-0AA0 is a 3-phase power choke weighing tens of kilograms with flat-type busbar terminals and no DIN-rail mounting. They serve different functions and occupy different panel zones.

MPN
4EU3622-0DA00-0AA0