Skip to main content
Siemens 4EU3622-4CA00-0AA0 — Line/Load Reactors

Siemens 4EU3622-4CA00-0AA0 Commutating Choke, 360A, 0.07mH,

MPN4EU3622-4CA00-0AA0

Siemens 4EU3622-4CA00-0AA0 commutating choke for converter, 3-phase, 500V AC, 50Hz, rated current 360A, maximum 400A, peak 500A, inductance 0.07mH, IP00, flat-type terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

4EU3622-4CA00-0AA0 specifications
ParameterValue
Type of voltageAC
Type of electrical connection for main current circuitflat connector
Operating voltage rated value500V
Relative inductive drop in voltage on the measurement level current, voltage and frequency4%
Peak current500A
Power loss [W] of the coil293W
Power loss [W] of the iron core182W
Operating frequency rated value50Hz
Phase number3
Ambient temperature rated value40°C
Depth0.227m
Width0.35m
Height0.321m
Thermal class acc. to IEC 60085H
Rated value360A
At DC rated value490.1A
Protection class IPIP00
Inductivity rated value0.00007H

Product details

The Siemens 4EU3622-4CA00-0AA0 is a three-phase commutating choke (line reactor) designed for converter front-ends. It limits current rise and reduces harmonic distortion on the AC line feeding a variable-frequency drive or DC drive. Rated 360 A continuous with a 400 A maximum and 500 A peak capability, it handles the inrush and transient loads typical of industrial drive systems. Inductance is 0.07 mH per phase at 50 Hz, with a relative inductive voltage drop of 4% at the rated current and voltage — a standard figure for commutating chokes that keeps voltage sag within acceptable limits for the DC bus. Operating voltage is 500 V AC, and the part carries a thermal class H (180 °C) insulation system per IEC 60085, meaning the winding can sustain higher temperature rises than class F or B designs — relevant if the choke sits in a warm cabinet or near the drive's heat sink.

Dimensions are 0.35 m wide by 0.321 m tall by 0.227 m deep; verify clearance for the flat-type main circuit terminals (bus-bar or cable lug connection) and for airflow around the core. Total power loss is 475 W (293 W in the coil plus 182 W in the iron core) at rated load and 40 °C ambient. That heat must be evacuated from the enclosure — factor it into the panel's thermal budget and consider forced ventilation if the cabinet is densely packed.

The part is UL and CSA recognized per EN 61558-2-20, which covers the safety of chokes and reactors. That recognition matters for panel builders who need a UL 508A listing on the overall assembly.

Frequently asked questions

How do I get current pricing and availability for 4EU3622-4CA00-0AA0?

Submit an RFQ through the storefront. Pricing and lead time are confirmed at quote time based on current market availability through our independent distribution network.

What compliance documentation does this brand provide for 4EU3622-4CA00-0AA0?

The part carries UL and CSA recognition per EN 61558-2-20. RoHS and REACH compliance documentation should be available from the manufacturer upon request; it is not explicitly listed in the product spec record.

MPN
4EU3622-4CA00-0AA0