Siemens 4EU3622-4DA00-0AA0 — Line/Load Reactors

Siemens 4EU3622-4DA00-0AA0 Commutating Choke, 500A, 690V AC

MPN4EU3622-4DA00-0AA0

Siemens 4EU3622-4DA00-0AA0 commutating choke for converter applications, 3-phase, 500A max, 450A rated, 690V AC, 73 µH, IP00, thermal class H.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Inductance & Impedance

4EU3622-4DA00-0AA0 — Inductance & Impedance
ParameterValue
Rated inductance0.000073H
Relative inductive voltage drop4%

Identification

4EU3622-4DA00-0AA0 — Identification
ParameterValue
Product designationKommut.-Drossel f. Stromrichter

Electrical

4EU3622-4DA00-0AA0 — Electrical
ParameterValue
Rated operating voltage690, 690V
Number of phases3
Rated current (DC)612.7A
Voltage typeAC
Rated operating frequency60 ... 50Hz
Peak current625A

Losses & Thermal

4EU3622-4DA00-0AA0 — Losses & Thermal
ParameterValue
Power loss, coil (W)390W
Power loss, iron core (W)180W
Rated ambient temperature40°C

Approvals

4EU3622-4DA00-0AA0 — Approvals
ParameterValue
Thermal class (IEC 60085)H

Mechanical

4EU3622-4DA00-0AA0 — Mechanical
ParameterValue
Main-circuit connection typeflat connector
IP protection ratingIP00
Height0.321m
Width0.35m
Depth0.227m

Product details

The Siemens 4EU3622-4DA00-0AA0 is a 3-phase commutating choke (line reactor) designed for converter front-ends in high-current power sections. It handles a maximum continuous current of 500A with a rated value of 450A at 690V AC, 50/60 Hz — sized for the input side of large drives or regenerative converters where the switching edges need smoothing and the fault current must be limited. The 73 µH inductance (0.000073 H) with a 4% relative inductive voltage drop at rated current means the choke presents enough impedance to reduce harmonic distortion and limit di/dt stress on the converter IGBTs. The 625A peak current rating covers short-duration overloads during motor acceleration or line transients.

Thermal and mechanical fit

Rated for 40°C ambient with thermal class H (180°C insulation system) per IEC 60085 — the winding can run hot under full load without degrading the insulation life. Total power loss splits into 390W in the coil and 180W in the iron core, so the panel needs to vent or force-air cool that 570W combined heat load. IP00 protection means it is an open-frame component — no enclosure, no ingress protection. Mount it inside a cabinet with clearance around the flat-type terminals (main current circuit connection) for busbar or cable lugs. Dimensions are 0.35m wide × 0.321m tall × 0.227m deep; plan the gland plate and busbar routing accordingly.